Eaton MPS86A4WEAXX2Q Magnum LV Power Breaker - UL Listed

Part Number: MPS86A4WEAXX2Q
Manufacturer
Eaton
Part number
MPS86A4WEAXX2Q

Quick Summary

The Eaton Magnum low voltage power circuit breaker protects industrial power systems by interrupting fault currents in distribution panels. A common challenge is nuisance tripping and slow fault isolation, which disrupts production and drives maintenance costs; Magnum PXR helps by delivering precise, coordinated protection. Certifications such as UL Listed, CE Marked, and NEMA Compliance support regulatory approvals and panel integration. With a 6000 A Iu rating and an 85 kAIC interrupt capacity, it scales to demanding loads while maintaining reliability. Designed for four-pole, drawout vertical mounting, it integrates with Power Xpert Protection Manager to streamline monitoring and lifecycle cost optimization.

Product Information

Extended Description

MPS86A4WEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NABCNABC), 85 kA, Four-pole, Drawout vertical mounting, PXR25 LSIAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86A4WEAXX2Q
UPC
786689630584
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked NEMA Compliant CCC Marked SABA Listed
Certifications
KEMA Certified UL Listed Lloyd's Register Certified ANSI CSA Certified DNV GL Certified ABS Certified
Frame
Double standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR25 LSI ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
6000 A
Interrupt rating
85 kAIC
Interrupt rating
85 kAIC
Rated uninterrupted current (Iu)
6000 A
Feature: High interrupt capability with 6000 A Iu and 85 kAIC protection. Business Impact: Enables safe interruption of large fault currents, reducing equipment damage and downtime; Application: suitable for data centers, process plants, and heavy industry where high fault-current events are possible. The Magnum PXR trip unit (LSI ARMS) ensures selective coordination, improving reliability and reducing unwanted trips in complex feeders. Feature: Drawout vertical mounting and a double standard frame. Business Impact: Simplifies installation, testing, and replacement without rearranging surrounding components; Application: ideal for retrofit projects and new panels in space-constrained switchgear. Feature: Four-pole configuration with robust frame design. Business Impact: Ensures balanced protection across all phases, improving system stability and protection accuracy; Application: critical loads and multi-pole feeders in manufacturing lines. Feature: Compliance and certifications including UL Listed, CE Marked, NEMA compliant. Business Impact: Facilitates faster panel approvals and regulatory compliance; Application: used in global projects with stringent standards. Feature: Power Xpert Protection Manager compatibility. Business Impact: Enables centralized protection management and remote diagnostics, lowering maintenance costs over the lifecycle; Application: enterprise-grade protection for critical processes and data integrity.

Get a Quick Quote for a Eaton MPS86A4WEAXX2Q

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS86A4WEAXX2Q? Enquire Now

FAQs

The unit uses a four-pole, drawout vertical-mount design within a double standard frame, matching standard low-voltage switchgear configurations. Ensure panel openings and mounting rails accommodate the 44.1 in width and 16.8 in height. The Magnum PXR trip unit can be field-configured for coordinated protection, simplifying retrofit projects and minimizing panel disruption.
Iu of 6000 A specifies the maximum uninterrupted current the breaker can carry under continuous loads, while 85 kAIC indicates the maximum fault current the device can interrupt without damage. Together, they support safe operation in high-demand circuits and provide clear guidance for selectivity and coordination during fault events.
Yes. The four-pole Magnum PXR unit is designed for high availability environments and heavy electrical loads typical of data centers and manufacturing lines. Its PXR25 LSI ARMS trip unit enhances selective coordination, reducing downtime due to mis-trips, while UL Listed and CE Marked certifications ease regulatory approvals in global facilities.
Key certifications include UL Listed, CE Marked, and NEMA Compliant, with additional approvals such as CCC, KEMA, ANSI, CSA, DNV GL, and ABS depending on region. These certifications support safe operation, cross-border panel approvals, and adherence to industry standards for electrical protection equipment.
Long-term reliability reduces downtime and maintenance frequency. The Power Xpert Protection Manager integration enables remote monitoring and diagnostics, lowering onsite service visits. Although upfront costs may be higher, the combination of improved protection coordination and centralized management translates to lower lifecycle costs and faster return on investment.