Eaton MPS86N3EEAXX2H Magnum Low-Voltage Breaker - UL/CE
Part Number: MPS86N3EEAXX2H
Quick Summary
Eaton Magnum low voltage power circuit breaker protects motor feeders in industrial switchgear and panels. In practice, uptime is jeopardized by nuisance trips, slow fault isolation, and difficult maintenance schedules. With CE Marked, UL Listed, CSA Certified and NEMA compliance, it meets global electrical codes and safety norms. Designed for Power Xpert Release integration, it supports selective coordination and rapid protection actions, helping engineers lower energy waste and maintenance costs. This model's drawout vertical design with extensions simplifies retrofits and serviceability on crowded bus ducts.
Product Information
Extended Description
MPS86N3EEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 85 kA, Three-pole, Drawout vertical with extensions mounting, PXR20 LSIAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N3EEAXX2H
UPC
786689640019
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked SABA Listed CCC Marked NEMA Compliant
Certifications
CSA Certified ANSI Lloyd's Register Certified UL Listed KEMA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS86N3EEAXX2H
Eaton Specification Sheet - MPS86N3EEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: PXR20 LSIAM trip unit delivers adjustable protection curves, fault reporting, and arc-energy data. Business Impact: Enables precise selective coordination across feeders, minimizing unneeded interruptions and shortening mean time to repair. Application: Ideal for motor feeders and distribution panels in process plants and heavy manufacturing. Feature: Drawout vertical with extensions mounting. Business Impact: Simplifies retrofits, testing, and future expansion, reducing installation time and field wiring complexity. Application: Fits standard vertical bus structures in MCCs and control panels. Feature: Three-pole configuration with 6000 A frame rating and 85 kA short-circuit rating. Business Impact: High fault current protection enables robust system reliability and reduces downstream equipment damage. Application: Heavy industrial distribution and machine-control circuits. Feature: Comprehensive certifications and compliance (CE, UL Listed, CSA Certified, NEMA Compliant). Business Impact: Regulatory readiness for global operations and safer installations, lowering compliance risk. Application: Global manufacturing sites and multi-region projects. Feature: Power Xpert Protection Manager compatibility and extensive installation resources. Business Impact: Centralized protection management, remote monitoring, and optimized maintenance planning. Application: Plants using Eaton’s automation stack and digital protection workflows. Feature: Access to time-current curves, renewal parts, and product documentation. Business Impact: Streamlined design verification and reduced lifecycle costs through easy parts replacement and informed maintenance.
Get a Quick Quote for a Eaton MPS86N3EEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N3EEAXX2H?
Enquire Now
FAQs
The MPS86N3EEAXX2H uses the PXR20 LSIAM trip unit and is designed for integration with Eaton’s Power Xpert Protection Manager, enabling centralized protection management and remote monitoring across switchgear, MCCs, and control panels.
The unit employs the PXR20 LSIAM trip unit, which provides adjustable protection curves, arc-energy data, and fault reporting. This enables precise selective coordination, faster fault isolation, and reduced downtime in motor feeder and distribution applications.
Yes. Its three-pole, drawout vertical design with extension mounting is well-suited for motor feeders and distribution panels in industrial settings, offering straightforward retrofits, easier serviceability, and robust protection with high interrupting ratings.
It carries CE Marked, UL Listed, CSA Certified, and NEMA Compliant certifications, along with other regional approvals. These certifications support regulatory compliance, product safety, and easier acceptance in global supply chains.
The breaker is rated for up to 85 kA short-circuit and a 6000 A frame, with a 3-pole configuration. Physical dimensions include 16.3 in depth, 16.8 in height, and 31.1 in width, with a weight of approximately 237 lb.