Eaton MPS86N3EEAXX2Q Magnum LV Breaker - UL Listed
Part Number: MPS86N3EEAXX2Q
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial power systems by interrupting faults in switchgear. Engineers often face downtime and performance penalties when protection coordination isn’t aligned with load profiles. It carries CE Marked, UL Listed, and CSA Certified markings to support global compliance and safer operation. The PXR25 LSIAM trip unit enables precise, selective tripping, minimizing nuisance outages while meeting critical safety standards. This solution offers robust fault protection, scalable mounting with drawout vertical extensions, and dependable performance that reduces maintenance interventions and total cost of ownership. Its rugged construction supports long service life in harsh industrial environments.
Product Information
Extended Description
MPS86N3EEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 85 kA, Three-pole, Drawout vertical with extensions mounting, PXR25 LSIAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N3EEAXX2Q
UPC
786689640026
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked CCC Marked SABA Listed NEMA Compliant
Certifications
CSA Certified KEMA Certified Lloyd's Register Certified ANSI UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS86N3EEAXX2Q
Eaton Specification Sheet - MPS86N3EEAXX2Q
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: The PXR25 LSIAM trip unit provides advanced protection and selective coordination, enabling precise fault isolation with minimal disturbance to healthy circuits. Business impact: This reduces nuisance trips, lowers process interruptions, and extends motor life by eliminating unnecessary interruptions. Application: Especially effective in motor control centers, power distribution panels, and critical feeders in heavy manufacturing where uptime matters. Feature: Drawout vertical mounting with extensions supports flexible installation and straightforward retrofits. Business impact: Simplifies alignment with existing bus systems, reduces commissioning time, and enables scalable protection schemes. Application: Use in legacy switchgear upgrades and new installations where space and mounting constraints require adaptable packaging. Feature: High interrupt capability — 6000 A frame rating with 85 kA short-circuit withstand on a three-pole unit. Business impact: Tolerates severe fault currents, enhancing plant safety and service continuity. Application: Suitable for main feeders and large motors in industrial plants and process facilities. Feature: Broad certifications including CE Marked, UL Listed, CSA Certified, plus KEMA and Lloyd’s Register attestations. Business impact: Reduces regulatory risk across global sites and simplifies procurement for multinational projects. Application: Ideal for facilities with strict compliance requirements across Europe, North America, and beyond. Feature: Compatibility with Power Xpert Protection Manager and other Eaton protection software; easy integration with protection management workflows. Business impact: Improves visibility, reduces maintenance overhead, and enables remote monitoring. Application: Useful for centralized control rooms, digital twin initiatives, and IoT-enabled plant modernization.
Get a Quick Quote for a Eaton MPS86N3EEAXX2Q
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N3EEAXX2Q?
Enquire Now
FAQs
Plan for a drawout vertical mounting configuration with extensions to fit existing bus systems. Verify enclosure space, clearance for extension modules, and proper alignment with mounting hardware. The unit’s 16.3 in length, 16.8 in height, and 31.1 in width require enclosure sizing and support structure evaluations prior to retrofit or new installation.
Key specs include three-pole operation, 6000 A frame rating, and 85 kA short-circuit capability, equipped with the PXR25 LSIAM trip unit for selective protection. This combination supports precise fault isolation, reduced nuisance trips, and robust performance in high-current feeders and motor circuits.
Yes. The three-pole Magnum breaker with drawout vertical mounting and PXR25 protection is designed for MCCs and main feeder applications. Its high interrupt rating and modular mounting support scalable protection schemes, making it well-suited for demanding manufacturing environments and large process facilities.
The unit is CE marked, UL Listed, and CSA Certified, with additional attestations from KEMA and Lloyd’s Register. These certifications support cross-border deployment, supplier qualification, and compliance with regional electrical codes across Europe, North America, and beyond.
By enabling selective tripping with the PXR25 unit and offering modular extensions for easy retrofits, it reduces downtime and maintenance interventions. Long-term reliability, durable construction, and compatibility with protection management tools further lower lifecycle costs and improve plant availability.