Eaton MPS86N3GEAXX2H Magnum Low-Voltage Breaker UL Listed
Part Number: MPS86N3GEAXX2H
Quick Summary
The Eaton Magnum low voltage power circuit breaker protects industrial motor circuits and distribution panels. In demanding plants, miscoordination and nuisance trips drive unplanned downtime and costly maintenance. The unit carries CE marking, UL Listed, and CSA Certified, with additional approvals from KEMA, Lloyd's Register, ABS, and DNV GL for global deployments. The Magnum leverages the Power Xpert Release trip unit and a motorized, drawout design to enable precise protection coordination and faster field service. With robust documentation and a clear installation path, this solution supports compliant, reliable panel builds and scalable protection modernization across global sites.
Product Information
Extended Description
MPS86N3GEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 85 kA, Three-pole, Drawout vertical with extensions and motorized racking mounting, PXR20 LSIAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N3GEAXX2H
UPC
786689640323
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked SABA Listed NEMA Compliant CCC Marked
Certifications
ANSI UL Listed CSA Certified KEMA Certified Lloyd's Register Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manual
Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manual
Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS86N3GEAXX2H
Eaton Specification Sheet - MPS86N3GEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: PXR20 LSIAM electronic trip unit enables precise, adjustable protection. Business Impact: improves selective coordination and reduces nuisance trips, boosting equipment uptime. Application: ideal for three-pole Magnum breakers in MCCs and power distribution panels. Feature: 85 kA interrupting rating with a 6000 A frame supports high fault current scenarios. Business Impact: minimizes arc energy and reduces equipment damage, lowering total cost of ownership. Application: heavy industry, mining, and large manufacturing facilities. Feature: Drawout vertical with extensions and motorized racking mounting enables safe, rapid maintenance. Business Impact: reduces downtime during replacement and commissioning; simplifies alignment and testing. Application: panelboards, switchgear, and control centers with tight maintenance windows. Feature: Comprehensive certifications and CE/UL/CSA approvals enable global deployment. Business Impact: mitigates procurement risk and accelerates project approvals across regions. Application: multinational projects requiring cross-border compliance. Feature: Documentation and interoperability with Power Xpert Protection Manager streamline commissioning. Business Impact: faster setup, easier updates, and better lifecycle management. Application: system integrators and OEMs deploying protective schemes and monitoring.
Get a Quick Quote for a Eaton MPS86N3GEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N3GEAXX2H?
Enquire Now
FAQs
The MPS86N3GEAXX2H ships with or is compatible with the PXR20 LSIAM trip unit, enabling precise protection coordination. It supports selective tripping schemes and easy parameter updates through Power Xpert software, helping engineers optimize protection settings for MCCs and feeder panels while reducing nuisance trips.
This is a three-pole Magnum unit with an 85 kA interrupting rating and a 6000 A frame. Physical dimensions are approximately 16.3 in depth, 16.8 in height, and 31.1 in width, with a weight around 237 lb. Certifications include UL Listed, CSA Certified, and CE Marked, with additional third-party approvals.
Yes. The drawout vertical design, with extensions and motorized racking mounting, is optimized for MCCs and panel boards. It enables safe maintenance, quick component replacement, and straightforward alignment, making it a strong fit for centralized motor protection and panel-level Schemes in manufacturing and process industries.
The unit carries UL Listed and CSA Certified marks, with CE marking and numerous third-party approvals including KEMA, Lloyd's Register, ABS, and DNV GL, supporting global deployment and regulatory compliance across regions.
The motorized racking and vertical interleaf design simplify field service, enabling faster maintenance and safer handle operations. Availability of zone interlocking application papers and Power Xpert documentation assists engineers in achieving efficient commissioning and reliable long-term protection.