Eaton Magnum LV circuit breaker - MPS86N3MEAXX2C 85 kAIC

Part Number: MPS86N3MEAXX2C
Manufacturer
Eaton
Part number
MPS86N3MEAXX2C

Quick Summary

The Eaton Magnum LV circuit breaker is a high-capacity protection device ideal for industrial power distribution. Engineers often face downtime during maintenance and the challenge of coordinating protection across large feeder networks. This unit carries UL Listed, CE Marked, CSA Certified, and ANSI Lloyd's Register certifications to meet global regulatory requirements and ensure dependable performance. With a PXR20 LSIG trip unit, motorized racking, and a drawout vertical mounting design, it balances precise protection with fast serviceability. Compatible with Magnum PXR systems, it delivers scalable protection for complex manufacturing lines, data centers, and process control environments, while helping to reduce total cost of ownership through extended maintenance intervals and standardized components.

Product Information

Extended Description

MPS86N3MEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 85 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSIG trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N3MEAXX2C
UPC
786689630294
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
SABA Listed CE Marked NEMA Compliant CCC Marked
Certifications
ANSI Lloyd's Register Certified UL Listed CSA Certified KEMA Certified ABS Certified DNV GL Certified
Frame
Double standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR20 LSIG
Number of poles
Three-pole
Rated uninterrupted current (Iu)
6000 A
Interrupt rating
85 kAIC
Interrupt rating
85 kAIC
Rated uninterrupted current (Iu)
6000 A
Feature: 6000 A Iu rating paired with an 85 kAIC interrupt capability. Business Impact: Enables safe interruption of high-energy faults without compromising downstream equipment, reducing downtime and damage costs. Application: Large motor feeders and distribution panels in heavy industry where fault energy can be significant. Feature: Three-pole, drawout vertical frame with motorized racking. Business Impact: Streamlines circuit breaker replacement and maintenance, minimizing plant downtime and improving safety during replacements. Application: Critical process lines and machine centers that require fast, touch-safe maintenance cycles. Feature: PXR20 LSIG trip unit. Business Impact: Provides advanced protection logic with sensitive ground fault and long-time protection coordination, enhancing selectivity and system reliability. Application: Complex manufacturing lines and multi-branch feeders needing precise coordination. Feature: Magnum PXR family compatibility (double standard frame). Business Impact: Allows seamless integration into existing Magnum PXR architectures, lowering retrofit risk and accelerating project timelines. Application: Upgrades to existing protection schemes in retrofit or expansion projects. Feature: Fan-cooled operation with robust environmental ratings. Business Impact: Improves thermal performance in densely packed switchgear, reducing nuisance trips and extending breaker life. Application: Packed control rooms and switchgear bays where heat can impact performance. Feature: Comprehensive certifications (UL Listed, CE Marked, CSA Certified, ANSI/Lloyd’s Register). Business Impact: Enables regulatory acceptance across regions, simplifying procurement and compliance audits. Application: Global deployments in automotive, food & beverage, and chemical processing facilities. Feature: Zone selective interlocking and documentation assets. Business Impact: Enhances selective coordination and provides design guidance for rapid, compliant implementations. Application: Large plant distributions requiring precise protection strategies and documented coordination.

Get a Quick Quote for a Eaton MPS86N3MEAXX2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS86N3MEAXX2C? Enquire Now

FAQs

Yes. The MPS86N3MEAXX2C features a drawout vertical mounting with motorized racking, designed to upgrade or replace breakers in Magnum PXR installations without extensive panel modifications. This enables safer, faster maintenance and simplified long-term serviceability.
Key specs include a 6000 A Iu rating and an 85 kAIC interrupt capability for each three-pole unit. Pairing with the PXR20 LSIG trip unit ensures coordinated protection for heavy motor loads and feeders, improving reliability and reducing fault energy impacts.
Yes. The unit carries UL Listed, CE Marked, CSA Certified, ANSI Lloyd’s Register certifications, along with additional compliances. Official certificates and product guides are available in Eaton’s download resources, including UL certificates and specification sheets.
Industries with complex protection coordination, such as automotive assembly, food & beverage processing, and chemical processing, benefit from Magnum PXR’s selective protection, motor protection, and rapid maintenance capabilities within double-standard frames.
The combination of a motorized racking solution, high interrupt rating, and broad certification coverage reduces downtime and commissioning risk, while long-term maintenance efficiency lowers lifecycle costs. Access to manuals and product aids further accelerates implementation and ongoing support.