Eaton MPS86N3MEAXX2H Magnum low voltage power circuit breaker - UL Listed

Part Number: MPS86N3MEAXX2H
Manufacturer
Eaton
Part number
MPS86N3MEAXX2H

Quick Summary

Eaton Magnum low voltage power circuit breaker protects personnel and equipment by reliably interrupting fault currents in industrial power systems. This model is designed for distribution panels, motor control centers, and other high-demand installations, helping reduce unplanned downtime. It carries CE Marked, UL Listed, and CSA Certified labels, along with ANSI/NEMA compliance, ensuring global applicability. With a Power Xpert Release trip unit and a motorized racking option, maintenance and replacement are safer and faster. For procurement teams, this rugged, scalable solution supports 237 lb units in a 6000 A withstand and 85 kA short-circuit rating, aligning with demanding plant protection while enabling efficient protection coordination.

Product Information

Extended Description

MPS86N3MEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 85 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSIAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N3MEAXX2H
UPC
786689630317
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked SABA Listed CCC Marked NEMA Compliant
Certifications
CSA Certified KEMA Certified UL Listed Lloyd's Register Certified ANSI ABS Certified DNV GL Certified
Trip unit sophistication with Power Xpert Release (PXR20 LSIAM) delivers precise, selective protection for motors and feeders. The business impact is fewer nuisance trips and faster fault clearance, improving uptime in manufacturing lines. This is especially valuable during peak loads or harmonics where accurate coordination matters for large drives and MCCs. Drawout vertical mounting with motorized racking simplifies maintenance and replacement cycles. The safety benefits are improved with controlled rack-in/out operations, reducing arc exposure and wiring disturbances. In retrofit projects, technicians can swap breakers without de-energizing entire panels, cutting downtime and saving labor costs. With 85 kA short-circuit rating and 6000 A withstand, the Magnum handles high fault currents without compromising selectivity. This translates to lower energy release and safer operation for critical feeders and machine feeders, enabling better protection coordination and reduced downstream damage. Three-pole configuration provides balanced protection across phases and aligns with standard MCC architectures, simplifying panel layouts and future expansion. Certifications such as CE Marked, UL Listed, CSA Certified, ANSI, and NEMA compliance assure regulatory alignment across regions, reducing audit findings and supporting cross-border deployments. At 16.3 in depth, 16.8 in height, and 31.1 in width, weighing 237 lb, the unit fits standard industrial frames, with fan cooling delivering reliable operation in demanding environments.

Get a Quick Quote for a Eaton MPS86N3MEAXX2H

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPS86N3MEAXX2H? Enquire Now

FAQs

This unit uses a drawout vertical mounting with motorized racking, so plan for a compatible panel, adequate clearance for rack-in/out, and space for fan cooling. Ensure electrical clearances align with the 16.3 in depth, 16.8 in height, and 31.1 in width footprint, and verify bus bar alignment for a smooth retrofit.
Key specs include three-pole operation, 6000 A short-circuit withstand, and 85 kA interrupting capacity. The PXR20 LSIAM trip unit provides advanced protection, and the unit weighs 237 lb with overall dimensions of 16.3 in L × 16.8 in H × 31.1 in W, suited for large feeders and motors.
Yes. Its three-pole frame, drawout design with motorized racking, and PXR20 protection are optimized for MCC environments, enabling easy maintenance, rapid changeouts, and reliable protection coordination for large motor drives and feeders.
The unit is CE marked and UL Listed, with CSA certification and additional compliance with ANSI/NEMA standards. It also features SABA listing and CCC marking, supporting global deployments and regulatory audits.
The PXR trip unit enables selective protection, reducing unnecessary trips and wear on downstream equipment. Motorized racking speeds maintenance, lowers downtime, and improves safety during replacements, delivering faster commissioning, easier service, and a measurable reduction in maintenance labor and outage duration.