Eaton MPS86N4EEAXX2C Low Voltage Power Circuit Breaker - UL Listed
Part Number: MPS86N4EEAXX2C
Quick Summary
MPS86N4EEAXX2C is a Magnum low voltage power circuit breaker designed for robust distribution protection in industrial facilities. Engineers often struggle with achieving reliable selective protection while minimizing arc exposure and downtime; this device addresses that by pairing a powerful protection platform with flexible integration. It carries critical certifications such as UL Listed, ANSI, and CSA, plus CE marking for global applicability, ensuring compliance across diverse markets. The combination of Power Xpert Release trip technology, a four-pole frame, and a drawout vertical design delivers tangible business value through safer operation, easier maintenance, and streamlined system commissioning.
Product Information
Extended Description
MPS86N4EEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 85 kA, Four-pole, Drawout vertical with extensions mounting, PXR20 LSIG trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N4EEAXX2C
UPC
786689640491
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CE Marked CCC Marked SABA Listed
Certifications
Lloyd's Register Certified ANSI CSA Certified KEMA Certified UL Listed DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS86N4EEAXX2C
Eaton Specification Sheet - MPS86N4EEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Feature: Magnum PXR20 LSIG trip unit enables precise protection and coordination. Business Impact: Improves selective coordination, reduces arc energy exposure, and limits fault scope to preserve uptime. Application: Industrial panels and distribution feeders where reliability and safety are paramount. Feature: Four-pole, 6000 A frame with an 85 kA interrupting capacity. Business Impact: Higher fault withstand and reduced risk of cascading trips in demanding load profiles. Application: Large-capacity power distribution in manufacturing lines and data centers. Feature: Drawout vertical with extensions mounting. Business Impact: Simplifies installation, inspection, and maintenance, cutting service time and labor costs. Application: Retrofit scenarios and retrofit-friendly installations in legacy systems. Feature: Wide certification coverage (UL Listed, ANSI, CSA, Lloyd’s Register, CE). Business Impact: Regulatory assurance and risk mitigation across global sites. Application: Global operations with strict compliance requirements. Feature: Compatibility with Magnum PXR trip units and Power Xpert protection ecosystem. Business Impact: Centralized control, easier integration with protection management software, and scalable protection strategy. Application: New builds and modernization projects leveraging Power Xpert suite for monitoring and analytics.
Get a Quick Quote for a Eaton MPS86N4EEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N4EEAXX2C?
Enquire Now
FAQs
The MPS86N4EEAXX2C uses the Magnum PXR trip unit platform (PXR20 LSIG) and is designed for drawout vertical mounting with extensions. This enables straightforward upgrades within existing panels and supports selective coordination practices, reducing retrofit complexity and labor while preserving existing bus and accessory layouts.
This breaker operates on a four-pole frame with a 6000 A (NNAABBCC) capacity and an 85 kA short-circuit rating. These ratings support high fault current environments found in large industrial installations, providing robust protection for feeders and motor circuits while enabling stable system performance.
The unit carries UL Listed, ANSI and CSA certifications, plus Lloyd’s Register, KEMA, DNV GL, ABS, and CE markings, along with NEMA compliance and CCC marking. This diverse certification set ensures global acceptance, regulatory alignment, and reduced risk in multinational projects and equipment procurement.
Yes. The combination of the PXR20 LSIG trip unit and the Magnum architecture supports selective coordination, while availability of zone selective interlocking references provides guidance for arc-energy reduction techniques. For deeper guidance, consult the Zone Selective Interlocking application paper to optimize protection schemes.
The vertical drawout design with extensions mounting simplifies removal and inspection, minimizing maintenance time and downtime. This configuration also supports easier field replacement of trip units or accessories and adds flexibility for future protection upgrades without major panel rework.