Eaton MPS86N4EEAXX2S Magnum LV Circuit Breaker - UL Listed
Part Number: MPS86N4EEAXX2S
Quick Summary
Eaton Magnum low voltage power circuit breaker protects electrical systems by interrupting fault currents in industrial power networks. For engineers and maintenance teams, nuisance trips and poor coordination can drive unplanned downtime and costly repairs. This product carries CE marking, UL listing, and NEMA compliance, with CSA and DNV GL certifications supporting global deployment. With the PXR25 LSIGAM trip unit and Power Xpert Release ecosystem, it delivers precise protection and simplified coordination, helping you reduce downtime while meeting regulatory requirements and improving panel reliability.
Product Information
Extended Description
MPS86N4EEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 85 kA, Four-pole, Drawout vertical with extensions mounting, PXR25 LSIGAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N4EEAXX2S
UPC
786689638139
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
SABA Listed CE Marked CCC Marked NEMA Compliant
Certifications
KEMA Certified Lloyd's Register Certified CSA Certified ANSI UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x32 22.06 1
Power Xpert Protection Manager x32 22.06 1
Eaton Specification Sheet - MPS86N4EEAXX2S
Eaton Specification Sheet - MPS86N4EEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Four-pole, drawout vertical mounting with extensions enables flexible installation and straightforward maintenance, reducing commissioning time and permitting staged testing without full disassembly. The PXR25 LSIGAM trip unit delivers advanced protection with adjustable settings, improving selectivity and fault clearance in demanding applications. The unit’s 6000 A frame rating and 85 kA short-circuit withstand enhance fault tolerance, reducing nuisance trips and protecting motors and drives under high fault currents. Comprehensive certifications including UL Listed, CE Marked, and NEMA compliance support global deployment and supply-chain consistency across multinational facilities. The physical footprint (16.3 in depth, 16.8 in height, 44.1 in width) and a heavy-duty 319 lb weight establish a durable platform suitable for large switchgear and drawout assemblies. Seamless integration with the Power Xpert Protection Manager and zone selective interlocking resources enables centralized protection strategy and faster corrective actions.
Get a Quick Quote for a Eaton MPS86N4EEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N4EEAXX2S?
Enquire Now
FAQs
The MPS86N4EEAXX2S is a four-pole, drawout vertical low-voltage circuit breaker with extensions mounting and vertical interleaf. It is designed for standard Magnum panels and supports a PXR25 LSIGAM trip unit. It integrates with Eaton's Magnum protection ecosystem and Power Xpert Protection Manager for streamlined installation and commissioning across machine builders and panel enclosures.
Key specifications include a 6000 A frame rating, 85 kA short-circuit withstand, four-pole configuration, drawout vertical mounting with extensions, and the PXR25 LSIGAM electronic trip unit. It is designed for reliable protection of motors and feeders in demanding industrial environments and supports zone interlocking for selective coordination.
The unit is UL Listed and CE Marked, with NEMA compliance. Additional certifications include CSA, KEMA, Lloyd's Register, ANSI, ABS, and DNV GL, providing broad regulatory and global market acceptance for multinational projects and varying panel systems.
Ideal for machine builders, process plants, and power distribution panels requiring reliable protection and coordination. The four-pole drawout design and Power Xpert Release trip unit support selective coordination, reducing mis-trips and enabling easier fault isolation in critical automation lines.
Renewal parts and accessories are available, with comprehensive manuals and support for long-term reliability. Zone selective interlocking papers and integration with Power Xpert Protection Manager help reduce downtime, improve safety, and lower lifecycle costs by streamlining maintenance and ensuring consistent protection across the plant.