Eaton MPS86N4MEAXX2Q Magnum low-voltage breaker - UL Listed
Part Number: MPS86N4MEAXX2Q
Quick Summary
Eaton Magnum low voltage power circuit breaker protects electrical distribution in industrial machinery by interrupting fault currents. Engineers often face downtime and costly maintenance when replacing or tripping breakers, and coordinating protection across large lines can be a challenge. With CE Marked, UL Listed, and NEMA compliant ratings, this Magnum unit supports global installations while meeting rigorous safety standards. The MPS86N4MEAXX2Q also leverages the Power Xpert Release trip unit and motorized racking to improve coordination and reduce downtime, delivering measurable business value through safer operations and streamlined maintenance.
Product Information
Extended Description
MPS86N4MEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 85 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N4MEAXX2Q
UPC
786689630386
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked NEMA Compliant SABA Listed CCC Marked
Certifications
KEMA Certified Lloyd's Register Certified ANSI UL Listed CSA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS86N4MEAXX2Q
Eaton Specification Sheet - MPS86N4MEAXX2Q
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Drawout vertical mounting with motorized racking improves service speed and safety, enabling technicians to rack the breaker without physical removal of heavy hardware in energized bays. This translates to shorter maintenance windows and reduced hot-work exposure, increasing plant uptime in harsh industrial environments. The PXR25 LSIAM trip unit provides precise, adjustable protection; combined with zone selective interlocking data and Power Xpert Protection Manager compatibility, it enhances selective coordination and reduces nuisance trips, supporting safer startup and smoother process control. A 6000 A frame rating and 85 kA short-circuit capacity ensure the unit withstands high fault currents common in metal processing and data-center environments, delivering robust protection with lower total cost of ownership. Four-pole, fan-cooled operation improves reliability and arc energy management in demanding applications, while the unit’s standard compliance with CE, UL, and NEMA frameworks simplifies global deployment. The Magnum MPS86N4MEAXX2Q is designed for quick installation alongside existing Magnum PXR trip units and offers straightforward maintenance with documented application notes and media to support field service teams. Overall, this solution supports longer mean time between outages and improved coordination across protection schemes in automation and power distribution networks.
Get a Quick Quote for a Eaton MPS86N4MEAXX2Q
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N4MEAXX2Q?
Enquire Now
FAQs
The unit uses a standard four-pole, drawout vertical arrangement compatible with typical switchgear bays. Ensure adequate space for motorized rack operation, proper clearance for maintenance, and alignment with existing Magnum PXR trip units. Follow the Eaton installation manual and verify UL and CE compliance during commissioning.
This model features a 6000 A frame and an 85 kA short-circuit rating, suitable for high-current applications. It is four-pole and fan-cooled, with the PXR25 LSIAM trip unit enabling advanced protection logic. Dimensions are 16.3 in (length/depth) x 16.8 in (height) x 44.1 in (width), and it weighs 319 lb.
Yes. The combination of a PXR25 LSIAM trip unit, four-pole configuration, and the option for zone selective interlocking supports selective coordination in complex automation lines, reducing the likelihood of unnecessary upstream tripping while improving overall system protection.
The breaker is CE marked and NEMA compliant, UL listed, and carries multiple certifications (KEMA, Lloyd's Register, CSA, ABS, DNV GL). This broad certification coverage supports global installation and regulatory compliance across industrial sectors.
Motorized racking streamlines maintenance by enabling faster, safer breaker replacement without manual extraction in energized spaces, reducing downtime and exposure to arc flash risks. Over time this can lower maintenance labor costs and improve equipment availability, contributing to a favorable total cost of ownership in automation and power distribution projects.