Eaton MPS86N4WEAXX2A Magnum low voltage power circuit breaker - UL Listed
Part Number: MPS86N4WEAXX2A
Quick Summary
Eaton MPS86N4WEAXX2A Magnum low voltage power circuit breaker is designed to protect electrical distribution systems in industrial facilities. Engineers often struggle with coordination, arc energy, and downtime when protection is inadequate, and this unit addresses those pain points with a robust PXR20 LSI trip unit and a reliable four-pole design. This product carries UL Listed, CSA Certified, and ANSI/Lloyd’s Register certifications, among others, ensuring global compliance. By combining a 6000 A frame rating with an 85 kA SCCR and a drawout vertical mounting, it offers scalable protection with easier maintenance and faster fault isolation, while supporting Power Xpert Release integration for modern protection schemes.
Product Information
Extended Description
MPS86N4WEAXX2A Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNAABBCC), 85 kA, Four-pole, Drawout vertical mounting, PXR20 LSI trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPS86N4WEAXX2A
UPC
786689630485
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked CCC Marked NEMA Compliant SABA Listed
Certifications
ANSI Lloyd's Register Certified KEMA Certified UL Listed CSA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manual
Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manual
Power Xpert Release trip unit for Magnum PXR circuit breakers PXR 20/25 user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPS86N4WEAXX2A
Eaton Specification Sheet - MPS86N4WEAXX2A
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Four-pole, drawout vertical mounting enables rapid maintenance and safe fault isolation in crowded switchgear assemblies, reducing downtime and labor costs. Business impact: faster servicing, improved safety, and simpler upgrades. Application: control panels and motor control centers in manufacturing lines. The PXR20 LSI trip unit provides adaptive protection and improved coordination, cutting arc energy exposure and enabling selective tripping in complex feeders. Application: large motors and critical loads. By delivering 85 kA SCCR and 6000 A frame rating, the Magnum breaker supports high fault currents with reliable interruption, boosting system reliability and compliance with industry standards. With UL Listed, CSA, and other certifications, it is ready for global deployment across markets, simplifying procurement and reducing certification gaps. Compatibility with Power Xpert Protection Manager and zone selective interlocking resources enhances remote monitoring, configuration, and maintenance planning, reducing on-site visits and improving overall lifecycle cost.
Get a Quick Quote for a Eaton MPS86N4WEAXX2A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPS86N4WEAXX2A?
Enquire Now
FAQs
Before installation, verify the panel enclosure supports four-pole, drawout breakers and vertical mounting. Check bus bar alignment, mounting rails, and enclosure clearance to accommodate the 16.3 in depth, 16.8 in height, and 44.1 in width. Ensure PXR20 LSI trip unit wiring is accessible, and configure with Power Xpert Protection Manager for monitored protection settings.
The PXR20 LSI trip unit provides load-sensing protection with advanced logic, enabling selective coordination and faster fault clearance. This reduces arc energy exposure, minimizes downstream damage risk, and improves uptime on motor feeders and critical loads, especially in high-demand industrial environments.
Ideal for industrial power distribution, motor control centers, and process lines requiring reliable protection with fast fault isolation. Its high SCCR and drawout design suit high-current, high-demand installations with frequent maintenance or replacement needs, while supporting scalable protection schemes for evolving plants.
The unit carries UL Listed and CSA Certified marks, plus ANSI certification, Lloyd’s Register and other global approvals. It also features CE marking and NEMA compliance, enabling installation across North America, Europe, and select international markets with confidence.
Expect reduced downtime from faster maintenance enabled by the drawout design, improved protection reducing fault events, and lower lifecycle costs through compatibility with Eaton protection software. Zone selective interlocking resources and comprehensive manuals support long-term reliability and streamlined field service.