Eaton MPSC083MEAXX2H Magnum LV Circuit Breaker - UL Listed
Part Number: MPSC083MEAXX2H
Quick Summary
The Eaton MPSC083MEAXX2H Magnum LV circuit breaker provides protection for molded case power distributions in industrial environments. Engineers often wrestle with nuisance trips, complex protection schemes, and lengthy maintenance windows that slow project timelines. This device carries CE Marked, UL Listed, and CSA Certified marks, among other stringent certifications, ensuring regulatory alignment across global markets. By leveraging the PXR20 LSIAM trip unit and motorized racking in a drawout vertical configuration, it delivers precise protection orchestration, rapid fault isolation, and safer maintenance. In practice, it supports reliable protection in switchgear and motor control centers, driving uptime, compliance, and overall lifecycle cost reduction for power distribution projects.
Product Information
Extended Description
MPSC083MEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 800 A, 100 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC083MEAXX2H
UPC
786689638924
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
CE Marked SABA Listed NEMA Compliant CCC Marked
Certifications
KEMA Certified CSA Certified Lloyd's Register Certified UL Listed ANSI ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC083MEAXX2H
Eaton Specification Sheet - MPSC083MEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature → Business Impact → Application: The Magnum low voltage power circuit breaker offers an 800 A rating and 100 kA short-circuit rating in a standard frame, enabling robust protection for high-demand feeders while supporting compact panel layouts. This translates to improved fault containment and reduced equipment damage, which is critical for critical processes in manufacturing and data centers. Application: main feeders and critical loads in switchgear, panelboards, and motor control centers. Feature → Business Impact → Application: PXR20 LSIAM trip unit provides advanced protection logic and precise trip settings, improving protection coordination and selectivity. This reduces unnecessary outages and extends motor life, benefiting process industries, pump rooms, and CNC facilities. Feature → Business Impact → Application: Drawout vertical mounting with motorized racking enables quick, safe maintenance and effortless breaker replacement, cutting downtime and labor costs during inspections and scheduled outages. Application: retrofit projects and new installations in heavy industry and power distribution environments. Feature → Business Impact → Application: Comprehensive compliance (CE Marked, SABA/NEMA/C CCC marks, UL Listed, CSA Certified, etc.) ensures regulatory acceptance and installation flexibility across regions. Application: multinational plants and compliance-driven facilities. Feature → Business Impact → Application: Weight and dimensions (118 lb, 14.6 in L, 16.8 in H, 16.2 in W) support manageable on-site handling and simplified transportation within crowded switchrooms. Application: plant rollouts, maintenance bays, and modular MCC assemblies. Feature → Business Impact → Application: Availability of extensive technical resources (spec sheets, coordination papers, installation guides) speeds engineering and commissioning. Application: engineering deliverables for projects requiring documented best practices and validated coordination.
Get a Quick Quote for a Eaton MPSC083MEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC083MEAXX2H?
Enquire Now
FAQs
Installations begin with confirming panel and busbar compatibility for a three-pole drawout device. Mount the breaker in the drawout rack, connect control and power terminals per the Magnum installation guide, and enable motorized racking for controlled insertion and withdrawal. Verify clearances, torque settings, and trip unit configuration for the PXR20 LSIAM, then perform a factory-referenced commissioning test to confirm correct protection and selectivity.
Key specs include an 800 A current rating and a 100 kA short-circuit withstand, three-pole construction, standard frame, and the PXR20 LSIAM trip unit. These enable enhanced protection coordination with fast, selective tripping for high-current faults, reducing nuisance trips and improving system reliability in feeders, MCCs, and critical loads.
Yes. The MPSC083MEAXX2H is designed for heavy-duty power distribution with robust trip coordination and a motorized racking option that minimizes maintenance downtime. Its 800 A rating and 100 kA interrupt capability fit MCC requirements, while UL/Ce/CSA certifications help satisfy industry-specific safety and regulatory standards.
This breaker carries UL Listed, CE Marked, CSA Certified, and additional certifications from bodies like KEMA, Lloyd's Register, ANSI, ABS, and DNV GL. These certifications support regulatory compliance across regions, facilitate supplier qualification during audits, and ensure the equipment meets recognized safety and performance benchmarks.
ROI benefits arise from reduced maintenance downtimes due to rapid racking, improved protection selectivity lowering outage duration, and extended asset life from precise fault isolation. Combined with regulatory compliance and faster commissioning, the Magnum PXR configuration lowers total cost of ownership in ongoing operations and project deployments.