Eaton MPSC123VEAXX2S Low Voltage Power Circuit Breaker - UL
Part Number: MPSC123VEAXX2S
Quick Summary
Eaton MPSC123VEAXX2S low voltage power circuit breaker protects critical electrical systems in industrial and utility-scale applications. It addresses common pain points like nuisance trips and coordination gaps that drive maintenance costs and downtime. The unit carries UL Listed, CE Marked, and ANSI/KEMA certifications, with additional Lloyd’s Register and CSA approvals for global deployment. Built for Magnum PXR protection, it combines a 1200 A continuous rating with 100 kAIC interrupt capability to safely clear faults. Seamless integration with Power Xpert Protection Manager enables remote monitoring and faster maintenance planning, while the fixed vertical mounting and standard frame simplify retrofits in existing MCCs and switchboards. This delivers reliable protection with scalable, code-compliant performance.
Product Information
Extended Description
MPSC123VEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1200 A, 100 kA, Three-pole, Fixed vertical mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC123VEAXX2S
UPC
786689638818
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
NEMA Compliant CCC Marked SABA Listed CE Marked
Certifications
ANSI KEMA Certified Lloyd's Register Certified UL Listed CSA Certified ABS Certified DNV GL Certified
Frame
Standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR25 LSIG ARMS
Number of poles
Three-pole
Rated uninterrupted current (Iu)
1200 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
1200 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC123VEAXX2S
Eaton Specification Sheet - MPSC123VEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
With a rated uninterrupted current (Iu) of 1200 A, the MPSC123VEAXX2S supports large feeders without overheating, reducing the risk of heat-related faults in dense panel racks. This translates to safer operation and longer service intervals, particularly in manufacturing lines and data-center auxiliary power rooms. The three-pole, standard-frame design aligns with common Magnum PXR configurations, enabling straightforward drop-in replacements and minimal wiring changes. Its 100 kA interrupt rating provides substantial fault current clearing capability, which is crucial in facilities with high short-circuit potential. The high breaking capacity improves protection for feeders and equipment, reducing arc flash exposure and collateral damage. In practice, engineers can rely on consistent performance during peak demand or short-circuit events. The PXR25 LSIG ARMS trip unit offers advanced zone-selective interlocking options and protection coordination, enabling selective tripping and reduced system-wide outages. This helps meet NEMA and UL coordination requirements while simplifying engineering studies and mitigations. Operators gain improved reliability in motors, drives, and switchgear networks. With fixed vertical mounting and a standard Magnum frame, installation fits neatly into existing enclosures and MCCs, minimizing retrofit complexity. The compact footprint (14.6 in depth, 16.2 in width, 16.8 in height) supports dense layouts without sacrificing accessibility for maintenance. Compatibility with Power Xpert software further enables remote status checks and fault history analysis. Certified for UL, CE, ANSI, KEMA, Lloyd's Register, CSA, ABS, and DNV GL, this breaker meets global installation requirements for regulated industries such as oil and gas, chemical processing, and critical manufacturing. The breadth of approvals reduces vendor variance and accelerates procurement cycles. In practice, owners gain lower total cost of ownership through reduced spare parts, streamlined commissioning, and longer service life.
Get a Quick Quote for a Eaton MPSC123VEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC123VEAXX2S?
Enquire Now
FAQs
Yes. The MPSC123VEAXX2S uses a Magnum standard frame and three-pole arrangement designed for straightforward drop-in replacement in existing MCCs and switchboards, minimizing wiring changes and enabling quicker retrofits.
Key specs include rated uninterrupted current (Iu) of 1200 A and interrupt rating of 100 kAIC, along with three-pole construction and a PXR25 LSIG ARMS trip unit, ensuring strong fault clearing with coordination capabilities.
Ideal for heavy-duty feeders in manufacturing, process industries, data centers, and power distribution panels where high fault currents, tight protection coordination, and reliable uptime are critical.
The product carries UL Listed and CE Marked certifications, plus ANSI, KEMA, Lloyd’s Register, CSA, ABS, and DNV GL approvals, supporting global deployment and regulatory compliance.
With remote monitoring via Power Xpert Protection Manager and robust protection features, it reduces unplanned downtime, simplifies maintenance planning, and lowers spare-parts inventory, delivering a favorable ROI through longer service life and fewer outages.