Eaton MPSC124HEAXX2F Magnum LV Breaker - 100 kAIC UL
Part Number: MPSC124HEAXX2F
Quick Summary
The Eaton Magnum MPSC124HEAXX2F provides reliable low-voltage protection for large panels and switchgear. Engineers often struggle with achieving precise coordination, minimizing nuisance trips, and speeding commissioning in complex feeders. This unit carries UL Listed, CE Marked, and CSA Certified credentials, along with Lloyd’s Register assurance, supporting global compliance. Combined with the Magnum PXR trip unit, it enables scalable protection strategies that improve selectivity while reducing downtime. Its standard frame, fixed horizontal mounting, and four-pole design simplify installation across mixed-panel layouts, delivering consistent protection in demanding environments and helping you meet project timelines and total-cost-of-ownership goals. For panel builders and end users, this translates to fewer field modifications, faster testing, and predictable maintenance windows.
Product Information
Extended Description
MPSC124HEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1200 A, 100 kA, Four-pole, Fixed horizontal mounting, PXR20 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC124HEAXX2F
UPC
786689639280
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
CCC Marked SABA Listed CE Marked NEMA Compliant
Certifications
ANSI CSA Certified Lloyd's Register Certified KEMA Certified UL Listed ABS Certified DNV GL Certified
Frame
Standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR20 LSIG ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
1200 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
1200 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC124HEAXX2F
Eaton Specification Sheet - MPSC124HEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Frame and mounting: The Magnum standard frame with fixed horizontal mounting keeps the breaker aligned with common panel buses, reducing field modification time. This translates to faster installations and fewer misalignments during switchgear upgrades, particularly in retrofits of four-pole feeders in MCCs. In practice, installers value repeatable mounting patterns that minimize commissioning risk. Application: Ideal for main distribution and large motor control centers where layout freedom and predictable fit speed project delivery. Electrical rating and capability: With a rated uninterrupted current (Iu) of 1200 A and a 100 kA interrupt rating, the MPSC124HEAXX2F delivers robust fault clearing for high-load feeders. This capability lowers the probability of cascading trips and supports safe, continuous operation in critical lines.Trip unit and coordination: PXR20 LSIGAM trip unit enables advanced protection logic and selective coordination. This improves system uptime by isolating only the faulted section, supports zone selective interlocking, and reduces arc energy exposure, all while aligning with modern protection standards.Compliance and compatibility: UL Listed, CE Marked, CSA Certified, and Lloyd’s Register verified, simplifying international deployments. The breaker integrates with the Magnum PXR ecosystem and Power Xpert Protection Manager for diagnostics, remote monitoring, and protection management—reducing现场现场 service time and improving asset visibility.Practical installation and ROI: Weighing 160 lb with dimensions of 14.6 in (D) × 16.8 in (H) × 21.2 in (W), it fits standard switchgear footprints and supports modular panel design. Long-term savings come from lower maintenance costs, easier spare parts sourcing, and extended service life through reliable protection performance.
Get a Quick Quote for a Eaton MPSC124HEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC124HEAXX2F?
Enquire Now
FAQs
The MPSC124HEAXX2F uses the standard Magnum frame with fixed horizontal mounting, designed for conventional low-voltage switchgear and four-pole feeders found in MCCs and large panel assemblies. Its dimensions and mounting pattern support straightforward retrofit into existing dashboards without extensive rewiring.
It provides 1200 A Iu rated current and a 100 kAIC interrupt rating, enabling robust fault clearance for high-load feeders and reducing the risk of cascading trips during short-circuit events.
Yes. The breaker is UL Listed and CE Marked, with CSA Certification and additional international attestations, supporting global compliance in cross-border projects.
Ideal for main distribution and motor control centers requiring high current protection, selectivity with the PXR20 LSIGAM trip unit, and scalable protection strategies across industrial facilities and manufacturing lines.
The PXR protection suite enables easier diagnostics and integration with Power Xpert Protection Manager, improving maintenance planning, reducing mean time to repair, and delivering longer asset life through precise protection and faster fault isolation.