Eaton MPSC124MEAXX2S Magnum PXR - UL Listed 100 kAIC
Part Number: MPSC124MEAXX2S
Quick Summary
The Eaton Magnum low voltage power circuit breaker MPSC124MEAXX2S delivers reliable protection for switchgear and motor circuits in industrial facilities. It addresses maintenance downtime and arc energy concerns with motorized racking and a PXR25 LSIGAM trip unit. It carries UL Listed, CE Marked, and Lloyd's Register Certified status, with ANSI and CSA certifications supporting global compliance. This four-pole, standard-frame breaker supports fast replacement in compact panels and enables precise protection coordination. Engineers benefit from improved uptime, easier documentation for audits, and a scalable solution that aligns with asset-management initiatives and plant-wide protection schemes.
Product Information
Extended Description
MPSC124MEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1200 A, 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC124MEAXX2S
UPC
786689639624
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
SABA Listed CE Marked NEMA Compliant CCC Marked
Certifications
Lloyd's Register Certified UL Listed ANSI KEMA Certified CSA Certified DNV GL Certified ABS Certified
Frame
Standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR25 LSIG ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
1200 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
1200 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC124MEAXX2S
Eaton Specification Sheet - MPSC124MEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Drawout vertical mounting with motorized racking. Business Impact: Reduces maintenance downtime and simplifies safe isolation during swaps, enabling faster kit replacements and lower labor costs. Application: Retrofit in legacy switchgear or new panel assemblies where quick access is required. Feature: Four-pole standard frame delivering 1200 A Iu. Business Impact: Supports large feeders and high-demand motor loads while preserving coordination with downstream protection. Application: Industrial plants, manufacturing lines, and data-center power distribution. Feature: PXR25 LSIGAM trip unit. Business Impact: Provides precise protection with selective coordination and low-energy arc management, improving system reliability. Application: Critical loads and motor-control centers. Feature: 100 kAIC interrupt rating. Business Impact: High fault-current capability reduces the risk of cascading failures and protects equipment. Application: Main feeders and high-demand switchgear in harsh industrial environments. Feature: Compliance and certifications. Business Impact: Global project acceptance and streamlined procurement with UL, CE, ANSI, CSA, and Lloyd’s Register credentials. Application: Multi-site deployments across regions with strict regulatory requirements. Feature: Compatibility with Magnum accessories and Power Xpert Protection Manager. Business Impact: Easier system integration, remote monitoring, and proactive maintenance planning. Application: Plant-wide protection strategies and digital asset management.
Get a Quick Quote for a Eaton MPSC124MEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC124MEAXX2S?
Enquire Now
FAQs
MPSC124MEAXX2S supports a four-pole, standard-frame configuration with drawout vertical mounting and motorized racking. This enables quick insertion and removal in compatible switchgear while maintaining safe operation. For retrofits, verify panel dimensions (14.6 in length, 16.8 in height, 21.2 in width) and ensure compatible mounting hardware and Eaton accessories are available.
Key ratings include rated uninterrupted current (Iu) of 1200 A and an interrupt rating of 100 kAIC. It uses the PXR25 LSIGAM trip unit, supports four poles, and comes in the Magnum standard frame. These specs enable reliable protection for large feeders and motor circuits in demanding industrial environments.
Yes. The four-pole design with a 1200 A Iu rating and 100 kAIC interrupt capability, combined with the LSIGAM trip unit, provides selective coordination and fast fault isolation for motor loads. This makes it well-suited for motorControl Centers (MCCs) and heavy-duty drives in manufacturing and processing plants.
The MPSC124MEAXX2S carries UL Listed and CE Marked credentials, with additional ANSI, CSA, and Lloyd’s Register certifications. It also aligns with SABA Listed and NEMA compliance, supporting global procurement and adherence to international electrical standards in multi-site deployments.
The motorized racking and drawout design reduce maintenance downtime by simplifying breaker replacement. Remote diagnostics through Power Xpert Protection Manager enable proactive maintenance, improving asset reliability and potentially lowering total cost of ownership through reduced plant downtime and streamlined commissioning.