Eaton MPSC163WEAXX2C Magnum LV Circuit Breaker - UL Listed

Part Number: MPSC163WEAXX2C
Manufacturer
Eaton
Part number
MPSC163WEAXX2C

Quick Summary

The Eaton MPSC163WEAXX2C Magnum LV circuit breaker is a robust overcurrent protector designed for industrial power distribution panels and machine rooms. This unit addresses panel downtime and nuisance trips by offering a precise, adjustable protection curve with a built-in LSIG trip option. With UL Listed, CSA Certified, and CE Marked certifications, it meets global compliance needs while supporting safe, reliable operations in harsh environments. The three-pole drawout device supports vertical mounting for easy maintenance, quick replacements, and reduced installation time. Coupled with Power Xpert Protection Manager compatibility, it provides actionable insights for protection coordination, asset reliability, and regulatory compliance across plant networks. It balances performance, safety, and total cost of ownership.

Product Information

Extended Description

MPSC163WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1600 A, 100 kA, Three-pole, Drawout vertical mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC163WEAXX2C
UPC
786689639488
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
SABA Listed NEMA Compliant CCC Marked CE Marked
Certifications
CSA Certified KEMA Certified Lloyd's Register Certified UL Listed ANSI ABS Certified DNV GL Certified
Feature → Business Impact → Application: High-current capacity and short-circuit withstand: 1600 A, 100 kA; reduces risk of cascading outages and equipment damage by delivering decisive fault clearing. Application: feeds large motors and robust process lines in heavy industrial facilities. Feature → Business Impact → Application: Drawout vertical mounting with standard frame: simplifies installation, rapid replacement, and easier maintenance planning; minimizes downtime during component swaps. Application: control cabinets and panel assemblies with frequent maintenance cycles. Feature → Business Impact → Application: PXR20 LSIG trip unit with programmable protection curves: enables precise long-time, short-time, and instantaneous settings for selective coordination; lowers outage impact while meeting safety requirements. Application: multi-panel, multi-device installations requiring coordinated protection. Feature → Business Impact → Application: Comprehensive compliance package (UL CSA CE) and documented certifications: reduces procurement risk and accelerates compliance audits. Application: regulated sectors such as oil & gas, water treatment, and automation lines. Feature → Business Impact → Application: Power Xpert Protection Manager compatibility: enables centralized protection management, monitoring, and faster fault diagnosis; improves asset lifecycle management. Application: modern control rooms and distributed architectures. Feature → Business Impact → Application: Availability of extensive application notes and datasheets: supports engineers with accurate installation guidance and integration steps. Application: project kickoff and retrofit projects needing clear reference material.

Get a Quick Quote for a Eaton MPSC163WEAXX2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC163WEAXX2C? Enquire Now

FAQs

For proper installation, ensure compatibility with the Magnum standard-frame, three-pole drawout design and vertical mounting. Verify panel space for a 14.6 in length, 16.2 in width, and 16.8 in height unit, align bus bars, and allow maintenance clearance for easy drawout. Follow Eaton’s mounting and torque guidelines and verify upstream protection coordination during commissioning.
The PXR20 LSIG trip unit provides configurable long-time, short-time, and instantaneous protection with LSIG options, enabling precise coordination with upstream devices. This reduces nuisance trips downstream, improves selectivity in multi-feed configurations, and supports faster fault isolation while maintaining system safety and reliability.
Yes. With a 1600 A rating, 100 kA interrupting capacity, three-pole design, and a configurable PXR20 LSIG trip unit, the breaker supports selective coordination across feeders and main breakers. This minimizes outages and maintains critical loads, which is essential for continuous operation in manufacturing, water treatment, and process industries.
The unit carries UL Listed, CSA Certified, CE Marked, along with other certifications such as KEMA and Lloyd’s Register. It also shows NEMA compliance and CCC Marking. These certifications simplify regulatory approval, qualify for multiple markets, and provide documented reliability and safety assurance for industrial installations.
ROI comes from reduced downtime due to reliable selective protection, longer service life, and easier maintenance with drawout design. Integration with Power Xpert Protection Manager enables centralized monitoring, faster fault diagnosis, and optimized protection settings across panels, lowering total cost of ownership and improving asset uptime.