Eaton MPSC164HEAXX2C Magnum low-voltage breaker - UL Listed

Part Number: MPSC164HEAXX2C
Manufacturer
Eaton
Part number
MPSC164HEAXX2C

Quick Summary

Eaton Magnum low voltage power circuit breaker protects electrical systems by interrupting fault currents in industrial and commercial power distributions. Operators often contend with nuisance trips, slow fault isolation, and fragmented protection schemes that drive downtime. This Magnum unit carries UL Listed and CSA Certified marks, CE and NEMA compliance, ensuring global acceptance and safe integration. Compatible with Power Xpert Release trip units and standard PXR protections, it supports scalable coordination for critical loads. With a 1600 A uninterrupted current rating and 100 kA interrupt capacity, it is designed for high-demand feeders and motor circuits. This combination supports faster fault clearance, improved uptime, and simpler procurement through a single, compliant solution.

Product Information

Extended Description

MPSC164HEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1600 A, 100 kA, Four-pole, Fixed horizontal mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC164HEAXX2C
UPC
786689638672
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
CE Marked CCC Marked SABA Listed NEMA Compliant
Certifications
KEMA Certified ANSI Lloyd's Register Certified UL Listed CSA Certified DNV GL Certified ABS Certified
Frame
Standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR20 LSIG
Number of poles
Four-pole
Rated uninterrupted current (Iu)
1600 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
1600 A
Feature: 100 kAIC interrupt rating with 1600 A Iu capacity. Business Impact: This enables fast, reliable fault clearance for high-demand feeders while limiting arc energy and equipment damage. Application: Ideal for large motor feeders and critical power circuits in industrial plants. Feature: PXR20 LSIG trip unit with Magnum PXR family compatibility. Business Impact: Delivers precise protection coordination and selective tripping to minimize disruption. Application: Useful in multi-panel switchgear where selective coordination is required. Feature: Four-pole, standard-frame, fixed horizontal mounting. Business Impact: Easy integration with existing bus systems and simple installation across multiple enclosures. Application: Consistent installation in new builds and retrofits in control panels. Feature: Global compliance—UL Listed, CSA Certified, CE Marked, NEMA Compliant. Business Impact: Reduces procurement risk, streamlines regulatory acceptance across markets. Application: Global data centers, manufacturing facilities, and critical power systems. Feature: Power Xpert Protection Manager compatibility and access to renewal parts and guides. Business Impact: Enables centralized protection management, faster device commissioning, and long-term serviceability. Application: Power management for facilities using Eaton protection ecosystem.

Get a Quick Quote for a Eaton MPSC164HEAXX2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC164HEAXX2C? Enquire Now

FAQs

The MPSC164HEAXX2C is designed with a standard Magnum frame, four-pole configuration, and fixed horizontal mounting, ensuring straightforward integration into compatible switchgear. It supports the Magnum PXR protection scheme and LSIG trip units, enabling seamless coordination with Eaton protection devices. For retrofit projects, verify panel busbar spacing and mounting clearance to confirm fit and alignment with your current protection strategy.
Key specs include a 1600 A Iu rated continuous current and a 100 kAIC interrupt rating, four-pole configuration, and a PXR20 LSIG trip unit. These characteristics enable robust fault clearance for high-demand feeders and reliable operation under short-circuit conditions. It also aligns with common LV circuit protection standards across regional markets.
Yes. The 100 kAIC interrupt capacity minimizes arc energy during faults, protecting motor loads and feeders. The LSIG trip unit provides precise, coordinated protection to reduce unnecessary trips, which is essential for manufacturing lines and critical power circuits. This makes it well-suited for large motors, pumps, and conveyors in industrial environments.
The unit carries UL Listed, CSA Certified, CE Marked, and NEMA Compliant certifications, with additional regional marks as applicable. These certifications support regulatory acceptance in multiple regions, simplify procurement for global projects, and help ensure safety, environmental, and performance requirements are consistently met across sites.
Maintenance considerations focus on readily available renewal parts, comprehensive datasheets, and compatibility with Eaton's protection management tools like Power Xpert Protection Manager. This enables faster commissioning, centralized configuration, and predictable service intervals, reducing field visits and improving uptime. Over the product life, this translates to lower total cost of ownership and easier spares planning.