Eaton MPSC164HEAXX2S Magnum LV circuit breaker - UL Listed

Part Number: MPSC164HEAXX2S
Manufacturer
Eaton
Part number
MPSC164HEAXX2S

Quick Summary

Eaton Magnum low voltage power circuit breaker protects electrical feeders in industrial control panels and switchgear. When uptime depends on reliable fault protection and precise coordination, choosing the right breaker reduces unplanned downtime and maintenance costs. These units are UL Listed, CE Marked, and NEMA Compliant, with additional KEMA Certified and ANSI/CSA certifications that support global deployment and compliance. The Magnum PXR trip unit with Power Xpert integration enables selective coordination and fast fault clearance, while the overall package offers strong business value through standardized procurement and easier maintenance across geographies. Engineers benefit from consistent labeling, standard interfaces, and compatibility with Magnum accessories.

Product Information

Extended Description

MPSC164HEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1600 A, 100 kA, Four-pole, Fixed horizontal mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC164HEAXX2S
UPC
786689639792
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
SABA Listed CCC Marked CE Marked NEMA Compliant
Certifications
KEMA Certified Lloyd's Register Certified UL Listed ANSI CSA Certified DNV GL Certified ABS Certified
High-current, high-availability protection is at the core of the MPSC164HEAXX2S. With a 1600 A rating and 100 kA short-circuit interrupting capability, this breaker supports robust feeders and main distribution networks, reducing the risk of cascading outages in heavy-load environments such as manufacturing lines and data centers. The four-pole, standard-frame design with fixed horizontal mounting provides reliable bus alignment and straightforward installation, accelerating panel fabrication and commissioning while maintaining space efficiency in compact switchgear racks. The PXR25 LSIGAM trip unit delivers precise protection and selective coordination, enabling faster fault clearance and improved uptime without compromising selectivity across downstream circuits. Its Power Xpert integration simplifies configuration and remote monitoring for proactive maintenance planning.

Get a Quick Quote for a Eaton MPSC164HEAXX2S

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC164HEAXX2S? Enquire Now

FAQs

The MPSC164HEAXX2S employs the PXR25 LSIGAM trip unit and is designed for seamless integration with Eaton's Power Xpert Protection Manager. This compatibility enables centralized configuration, real-time monitoring, and easier upgrade paths for selective coordination across feeders. For new installations, you can plan protection schemes that align with existing PXR devices and migration strategies when expanding switchgear networks.
Fixed horizontal mounting supports stable bus bar alignment and straightforward wiring routes, reducing field assembly time. The four-pole design fits standard Magnum frames and enclosure footprints, allowing predictable clearances and easier access for maintenance. Ensure mounting brackets and access room align with the 14.6 in depth, 16.8 in height, and 21.2 in width specifications, and verify compatibility with downstream devices in the cabinet.
Yes. The MPSC164HEAXX2S is rated for 100 kA short-circuit capability and 1600 A continuous current, which supports selective coordination strategies in medium- to large-size distribution schemes. For optimal performance, coordinate with downstream protection devices, verify arc-flash considerations, and leverage the PXR25 LSIGAM trip unit’s settings to maintain selectivity across levels.
The unit carries UL Listed, CE Marked, and NEMA Compliant certifications, with additional KEMA, ANSI, CSA, DNV GL, ABS, and Lloyd's Register certifications available. This broad certification profile supports global deployments, assists with meeting local electrical codes, and reduces procurement risk for multinational projects.
Maintenance benefits come from standardized Magnum components, the PXR trip unit for straightforward field configuration, and compatibility with Power Xpert tools for remote diagnostics. Although initial costs may be higher than basic breakers, the protection reliability, reduced downtime, and easier upgrades can yield favorable total cost of ownership over the equipment life cycle.