Eaton Magnum low voltage power circuit breaker MPSC164VEAXX2S - UL Listed
Part Number: MPSC164VEAXX2S
Quick Summary
Eaton Magnum low voltage power circuit breaker MPSC164VEAXX2S protects distribution panels by interrupting fault currents in industrial settings. Engineers often struggle with protecting large, interconnected loads without nuisance trips or coordination gaps. UL Listed, CE Marked, and CSA Certified ensure regulatory compliance and reliable performance across global markets. Power Xpert Release (PXR) trip unit compatibility and the fixed vertical four-pole design enable safer, easier integration into existing Magnum frames, delivering faster commissioning, reduced downtime, and lower lifecycle costs for industrial automation and power distribution applications.
Product Information
Extended Description
MPSC164VEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1600 A, 100 kA, Four-pole, Fixed vertical mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC164VEAXX2S
UPC
786689639174
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
NEMA Compliant SABA Listed CE Marked CCC Marked
Certifications
KEMA Certified UL Listed Lloyd's Register Certified CSA Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC164VEAXX2S
Eaton Specification Sheet - MPSC164VEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The MPSC164VEAXX2S uses a Power Xpert Release (PXR) trip unit to deliver precise protection settings, improving coordination and reducing arc-flash risk in complex power networks. This translates to measurable business impact: fewer nuisance trips, enhanced motor protection, and smoother startup sequences for automated lines. In practice, the four-pole, fixed vertical mounting on a standard frame simplifies retrofits and maintenance across plant floors, enabling quick upgrades to existing panels and consistent protection across all feeders. With a 1600 A rating and 100 kA interrupt capacity, this breaker supports high-demand motor circuits and critical loads, delivering reliable short-circuit clearance and protecting valuable equipment. Compliance with UL, CE, and CSA standards assures auditors and customers of robust safety and regulatory alignment, while Power Xpert Protection Manager compatibility enables remote monitoring and event data analysis for proactive maintenance. The combination of documented specifications, accessory coverage, and Eaton support ecosystem reduces total cost of ownership and accelerates project timelines in power distribution upgrades.
Get a Quick Quote for a Eaton MPSC164VEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC164VEAXX2S?
Enquire Now
FAQs
This unit uses a standard Magnum frame with fixed vertical mounting, designed for straightforward retrofit into compatible LV panels. Ensure the panel supports four-pole, 1600 A devices and follow Eaton's installation guides for bus bar and neutral connections, torque specs, and trip unit configuration (PXR25 LSIGAM).
Key specifications include four-pole construction, 1600 A current rating, 100 kA interrupting capacity, and the Power Xpert Release (PXR) 25 LSIGAM electronic trip unit, within a standard frame for reliable, scalable protection.
Yes. The 1600 A rating, 100 kA short-circuit capacity, and PXR trip-unit protection support robust motor protection and selective coordination in automation panels, helping reduce nuisance trips and downtime in motor-driven processes.
The device is UL Listed, CE Marked, and CSA Certified, with additional approvals including KEMA, Lloyd's Register, ANSI, DNV GL, and ABS certifications, supporting global deployment and compliance requirements.
Its robust protection system reduces unplanned outages, and its compatibility with Power Xpert Protection Manager enables remote monitoring and data-driven maintenance. The standard frame and modular trip unit simplify replacements and upgrades, delivering lower lifecycle costs.