Eaton MPSC164WEAXXSW Magnum LV CB - UL Listed

Part Number: MPSC164WEAXXSW
Manufacturer
Eaton
Part number
MPSC164WEAXXSW

Quick Summary

Eaton Magnum low voltage power circuit breaker protects industrial power distribution and machine systems. This four-pole unit with drawout vertical mounting helps minimize downtime during installation and maintenance. It carries UL Listed, CSA Certified, and CE Marked certifications, ensuring compliance across global panels. Although shipped without a trip unit, it is compatible with Power Xpert Release trip units for scalable protection and pairs with Magnum PXR protection in modern control cabinets to support selective coordination and future upgrades.

Product Information

Extended Description

MPSC164WEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 1600 A, 100 kA, Four-pole, Drawout vertical mounting, No trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC164WEAXXSW
UPC
786689639181
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
NEMA Compliant CE Marked SABA Listed CCC Marked
Certifications
CSA Certified ANSI UL Listed KEMA Certified Lloyd's Register Certified ABS Certified DNV GL Certified
Drawout vertical mounting and a four-pole configuration simplify integration into large switchboards, enabling safe, tool-assisted replacement with minimal panel disturbance. This design reduces commissioning time and boosts maintenance efficiency in high-density panels. High current rating of 1600 A and a 100 kA breaking capacity provide robust protection against severe short circuits, safeguarding feeders and motors while limiting fault damage and downtime. The unit ships as a no-trip-unit device, offering flexibility to install a Power Xpert Release trip unit (PXR) for advanced protection features, including selective coordination and zone-selective interlocking when required by the application. Certifications including UL Listed, CSA Certified, ANSI, CE Marked, and independent attestations (KEMA, Lloyd’s Register, ABS, DNV GL, SABA, CCC) simplify procurement and regulatory compliance across regions. The heavy-duty construction and 160 lb chassis support long service life and reliable performance under demanding industrial conditions, reducing maintenance cycles and improving overall equipment uptime. The package is compatible with Magnum PXR protection ecosystems, enabling future upgrades without replacing the base breaker, which translates to lower total cost of ownership in evolving control architectures. Application versatility spans panel boards, switchgear, and high-load industrial environments such as manufacturing lines and process industries.

Get a Quick Quote for a Eaton MPSC164WEAXXSW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC164WEAXXSW? Enquire Now

FAQs

This four-pole, drawout vertical unit is designed for installation into standard low-voltage panels. Ensure proper alignment with mounting rails, confirm secure drawout engagement, and use compatible wiring and lugs. Note that this variant ships without a trip unit, so plan for installing a Power Xpert Release trip unit (PXR) if advanced protection, selective coordination, or interlocking is required. Refer to the Magna PXR manuals for installation guidance and weight considerations (approximately 160 lb).
The MPSC164WEAXXSW is a four-pole breaker rated at 1600 A with a 100 kA breaking capacity, suitable for high-current feeders and motor circuits. It is designed for drawout vertical mounting and ships without a trip unit, allowing future upgrade to a PXR protection scheme.
Yes. While shipped without a trip unit, the breaker is compatible with Power Xpert Release trip units for Magnum PXR, enabling selective coordination. For zone selective interlocking, consult Eaton application papers and the Zone Selective Interlocking guidance to ensure proper system integration.
The MPSC164WEAXXSW carries UL Listed and CSA Certified marks, along with CE marking and additional third-party certifications (KEMA, Lloyd’s Register, ABS, DNV GL, SABA, CCC, etc.). These certifications support regulatory compliance, global procurement, and safe operation in multi-region facilities, simplifying panel approvals and reducing supplier risk.
The four-pole drawout design supports safer, faster maintenance and replacement, reducing downtime. Compatibility with PXR trip units allows future protection upgrades without changing the base breaker, lowering total cost of ownership. High fault-current protection (1600 A, 100 kA) helps safeguard downstream equipment, potentially reducing repair costs and improving system uptime.