Eaton MPSC204HEAXX2S Magnum LV circuit breaker - 100 kAIC

Part Number: MPSC204HEAXX2S
Manufacturer
Eaton
Part number
MPSC204HEAXX2S

Quick Summary

The Eaton Magnum LV circuit breaker MPSC204HEAXX2S provides reliable overcurrent protection for demanding low-voltage power distribution systems. In practice, engineers need protection that trips reliably without nuisance outages during startup or fault conditions. This unit carries UL Listed and ANSI certifications, with KEMA, Lloyd’s Register, CSA, DNV GL, and ABS attestations, plus CE marking for global compliance. Rated for four poles with a 2000 A Iu and a 100 kAIC interrupt rating, it uses the PXR25 LSIGAM trip unit for selective coordination. Fixed horizontal mounting and compatibility with Magnum PXR trip units streamline installation in switchgear. Together, these features support uptime, regulatory alignment, and reduced lifecycle costs for industrial facilities.

Product Information

Extended Description

MPSC204HEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 2000 A, 100 kA, Four-pole, Fixed horizontal mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC204HEAXX2S
UPC
786689637156
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
NEMA Compliant CE Marked CCC Marked SABA Listed
Certifications
KEMA Certified ANSI Lloyd's Register Certified CSA Certified UL Listed DNV GL Certified ABS Certified
Frame
Standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR25 LSIG ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
2000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
2000 A
High current rating and robust interrupt capability deliver fast fault clearing for feeders, protecting downstream equipment and minimizing arc energy. This translates to shorter outages and lower repair costs in demanding applications such as data centers, heavy manufacturing, and large motor drives. The 2000 A Iu and 100 kAIC rating enable reliable performance under peak loads and fault conditions. The PXR25 LSIGAM trip unit provides selective coordination, so only the faulted section trips, preserving uptime for non-affected circuits in process plants and mission-critical facilities. Four-pole configuration with a standard frame and fixed horizontal mounting simplifies field installation, reduces wiring complexity, and improves rack compatibility in switchgear. The broad certifications—UL Listed, ANSI, KEMA, LR, CSA, CE, NEMA, CCC—facilitate global procurement and regulatory approvals, while extensive technical resources and Power Xpert Protection Manager compatibility accelerate commissioning and ongoing maintenance.

Get a Quick Quote for a Eaton MPSC204HEAXX2S

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC204HEAXX2S? Enquire Now

FAQs

The MPSC204HEAXX2S is designed for fixed horizontal mounting in standard switchgear frames. With a four-pole configuration and a standard frame, it drops into common LV panels without adapters. Dimensions and mounting alignment (14.6 in depth, 16.8 in height, 21.2 in width) support straightforward field installation, minimizing commissioning time and reducing the need for custom hardware.
Key specs include a 2000 A Iu rating and a 100 kAIC interrupt rating, four poles, and the PXR25 LSIGAM trip unit. This combination enables high-capacity protection with selective coordination, ensuring fast fault clearance while limiting outages to affected sections. The unit is suitable for large feeders, motor drives, and critical processes in industrial environments.
Yes. The Magnum PXR family integrates with Eaton's Power Xpert Protection Manager, enabling centralized monitoring, event reporting, and coordinated protection across multiple devices. This compatibility supports faster commissioning, proactive maintenance, and improved visibility into protection schemes for engineers managing complex LV installations.
The MPSC204HEAXX2S carries UL Listed and ANSI certifications, plus KEMA, Lloyd's Register, CSA, DNV GL, and ABS attestations, along with CE marking and other compliance marks such as NEMA and CCC. This broad certification portfolio reduces procurement risk and eases cross-border approvals for global projects.
Maintenance is typically driven by routine inspection of protection schemes and routine verification of trip unit settings. The PXR25 LSIGAM unit’s reliable coordination reduces nuisance trips, lowering maintenance interruptions. A well-implemented Magnum PXR protection strategy can shorten downtime, extend asset life, and improve overall ROI by stabilizing production uptime and reducing unplanned outages.