Eaton MPSC204WEAXX2C Magnum low voltage power circuit breaker - UL Listed
Part Number: MPSC204WEAXX2C
Quick Summary
The Eaton Magnum low voltage power circuit breaker protects industrial electrical systems from overloads and short circuits. Engineered for critical lines in manufacturing plants and data centers, it minimizes downtime by delivering proven protection and selective coordination. This model features the Power Xpert Release (PXR) trip unit along with a 2000 A rating and 100 kA interrupt capacity, backed by UL Listed, CE Marked, and NEMA compliant certifications for global projects. Its drawout vertical mounting and standard frame enable straightforward retrofits and serviceability, while compatibility with Magnum PXR protection supports scalable protection schemes in switchgear, motor control centers, and power distribution assemblies.
Product Information
Extended Description
MPSC204WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 2000 A, 100 kA, Four-pole, Drawout vertical mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC204WEAXX2C
UPC
786689637484
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
CCC Marked CE Marked SABA Listed NEMA Compliant
Certifications
KEMA Certified ANSI Lloyd's Register Certified CSA Certified UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC204WEAXX2C
Eaton Specification Sheet - MPSC204WEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Drawout vertical mounting on a standard frame enables safe, fast replacement without wiring disruption. Business Impact: Reduces maintenance downtime and simplifies field service, improving plant availability. Application: Ideal for switchgear banks and retrofit projects in industrial environments. Feature: 2000 A current rating with 100 kA interrupt capacity provides robust protection for high-current feeders. Business Impact: Limits arc-flash risk and minimizes unplanned outages, supporting reliable production lines. Application: Heavy manufacturing, data centers, and mission-critical machinery. Feature: Power Xpert Release PXR20 LSIG trip unit offers adjustable protection and selective coordination. Business Impact: Improves fault isolation accuracy and reduces nuisance trips, lowering maintenance costs. Application: Motor control centers and panel upgrades requiring precise coordination. Feature: Four-pole design with drawout capability supports balanced phase protection and easy integration with existing switchgear. Business Impact: Enhances system reliability and simplifies commissioning in complex electrical rooms. Application: Large-scale distribution, control panels, and industrial automation cabinets. Feature: Broad certifications including UL Listed, CE Marked, and NEMA Compliant ensure regulatory readiness and global applicability. Business Impact: Accelerates project approvals and reduces risk during cross-border deployments. Application: Global manufacturing facilities, OEM installations, and energy-efficient projects. Long-tail keywords such as low voltage circuit breaker, Magnum PXR, drawout breaker, motor control centers, and selective coordination are embedded to reflect real-world search patterns.
Get a Quick Quote for a Eaton MPSC204WEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC204WEAXX2C?
Enquire Now
FAQs
The MPSC204WEAXX2C uses a drawout vertical mounting with a standard frame, designed for straightforward field replacement in switchgear banks and motor control centers. Plan for typical 14.6 in depth, 16.8 in height, and 21.2 in width footprint, plus service clearance for hot-swapping and testing. Ensure compatibility with existing Magnum PXR protection modules and matching bus bar configurations.
This breaker is rated for 2000 A continuous current with a 100 kA interrupt capacity, providing robust protection for high-current feeders. It includes the Power Xpert Release PXR20 LSIG trip unit, offering adjustable protection settings and coordinated tripping to minimize the impact of faults on adjacent circuits.
Yes. With a 2000 A rating and 100 kA short-circuit capability, the MPSC204WEAXX2C suits data centers, heavy machinery, and large manufacturing lines. Its four-pole design and PXR protection support selective coordination, reducing downtime and enabling reliable power distribution in critical facilities.
The unit carries UL Listed, CE Marked, and NEMA compliant status, along with additional certifications including KEMA, ANSI, Lloyd's Register, CSA, ABS, and DNV GL. This broad certification suite supports compliance in North American, European, and global installations, streamlining procurement and approvals.
Eaton offers Magnum renewal parts and accessories for ongoing lifecycle support. The PXR trip unit and related components can be upgraded or serviced as part of preventive maintenance programs, helping sustain protection performance, reduce unplanned downtime, and extend service life in critical switchgear and control panels.