Eaton MPSC253MEAXX2C Magnum LV CB - UL Listed
Part Number: MPSC253MEAXX2C
Quick Summary
Eaton MPSC253MEAXX2C is a Magnum low-voltage circuit breaker used to protect industrial power distribution in panels. Manufacturers and maintenance teams often battle nuisance trips, miscoordination, and outages that slow production. It carries CE marking, UL listing, and NEMA compliance, plus additional global certifications that support installation across markets. With the Power Xpert Release trip unit and a motorized, drawout vertical racking design, it enables precise protection and faster service while meeting stringent safety and reliability requirements. This combination delivers business value by improving uptime, simplifying protection management, and reducing spare parts and maintenance costs in power cabinets and motor control centers.
Product Information
Extended Description
MPSC253MEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 2500 A, 100 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC253MEAXX2C
UPC
786689637743
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
SABA Listed CCC Marked CE Marked NEMA Compliant
Certifications
Lloyd's Register Certified UL Listed ANSI CSA Certified KEMA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC253MEAXX2C
Eaton Specification Sheet - MPSC253MEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Power Xpert Release PXR20 LSIG trip unit provides adjustable protection curves and enhanced diagnostic communication. Business Impact: sharper fault detection, reduced nuisance trips, and improved coordination with downstream devices. Application: ideal for large panels and motor control centers that require selective coordination. Feature: 2500 A standard frame with 100 kA interrupting rating ensures robust fault tolerance. Business Impact: higher system reliability, minimized downtime, and easier load rebalancing. Application: heavy-load feeders and critical power paths in manufacturing and data centers. Feature: Drawout vertical mounting with motorized racking enables fast, safe maintenance and reduced outage duration. Business Impact: safer service windows and decreased commissioning time. Application: retrofit and new installs in control panels and MCCs. Feature: Comprehensive certification suite (CE, UL Listed, NEMA Compliant, ANSI, CSA, KEMA, etc.). Business Impact: procurement risk reduction and faster regulatory acceptance. Application: global projects demanding standards compliance. Feature: Three-pole, standard frame with documented dimensions (14.6 in L, 16.8 in H, 16.2 in W) and 118 lb weight. Business Impact: predictable fit in existing racks and easier handling during installation. Application: panel boards, compact MCCs, and retrofit installs.
Get a Quick Quote for a Eaton MPSC253MEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC253MEAXX2C?
Enquire Now
FAQs
Plan for a drawout vertical installation with motorized racking, ensuring the breaker footprint fits the existing rack spacing and busbar arrangement. Verify clearance for racking operations, lubrication points, and PXR20 LSIG trip unit accessibility. Confirm compatible protection devices in the same protection scheme to maintain selective coordination and minimize nuisance trips during maintenance.
The PXR20 LSIG trip unit provides advanced protection logic with adjustable curves, faster fault recognition, and integrated diagnostics. This enables precise coordination with downstream devices, reduces nuisance trips, and supports protection management through Power Xpert software, improving uptime and enabling proactive maintenance planning in complex power distribution systems.
The MPSC253MEAXX2C carries UL Listed and CE Marking, along with NEMA compliance and additional certifications from ANSI, CSA, KEMA, ABS, and DNV GL. This broad certification portfolio supports procurement across international projects, streamlines approvals, and reduces the risk of non-compliance in regulated industries.
Yes. With its drawout vertical mounting, motorized racking, and three-pole, standard-frame design, the MPSC253MEAXX2C is well-suited for MCC applications. It supports quick maintenance, safe servicing, and reliable protection coordination in panels that manage large motors and high inrush loads.
The combination of a high interrupting rating (100 kA), advanced PXR trip unit, and motorized racking reduces downtime and maintenance labor. Improved selective coordination minimizes downstream faults, lowering spare parts consumption and extending mean time between failures, ultimately delivering faster return on investment in critical manufacturing and processing environments.