Eaton MPSC253VEAXX2H Magnum LV Circuit Breaker - UL 100 kA

Part Number: MPSC253VEAXX2H
Manufacturer
Eaton
Part number
MPSC253VEAXX2H

Quick Summary

An Eaton Magnum LV circuit breaker provides reliable overcurrent protection for industrial power distribution in control panels and motor feeders. Engineers often grapple with nuisance trips, uneven coordination, and costly downtime during faults. UL Listed, CE Marked, and ANSI certifications support global compliance and safer operation. Coupled with the PXR20 LSIAM trip unit and Power Xpert Compatibility, this breaker helps you optimize protection coordination and uptime. This translates to measurable business value, including shorter fault clearance times, reduced unplanned outages, and improved reliability in critical processes. For panel builders and system integrators, the fixed vertical mounting and standard frame simplify installation, stocking, and spare part planning.

Product Information

Extended Description

MPSC253VEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 2500 A, 100 kA, Three-pole, Fixed vertical mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC253VEAXX2H
UPC
786689636791
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
CCC Marked SABA Listed CE Marked NEMA Compliant
Certifications
KEMA Certified CSA Certified Lloyd's Register Certified ANSI UL Listed ABS Certified DNV GL Certified
Feature: 2500 A current rating with a 100 kA short-circuit interrupting capability. Business Impact: Supports high-demand feeders and large motor circuits without frequent replacements, reducing total cost of ownership. Application: Main feeders and motor control centers in heavy-industrial installations. Feature: PXR20 LSIAM electronic trip unit. Business Impact: Enables precise, adjustable protection and selective coordination, lowering nuisance trips and enabling faster fault isolation. Application: Process lines, pumps, and drives where downtime directly impacts throughput. Feature: Standard frame with fixed vertical mounting. Business Impact: Streamlines installation in existing panels and simplifies retrofit projects, reducing commissioning time. Application: Retrofit and new-build panels in manufacturing environments. Feature: Comprehensive certifications and compliance. Business Impact: Facilitates regulatory adherence across multiple regions, reducing risk during inspections and audits. Application: Global facilities requiring CE, UL, ANSI, and other recognized certifications. Feature: Robust physical spec (dimensions and weight). Business Impact: Provides clear space planning and supporting structural integrity in rugged environments. Application: Enclosures with standard bay layouts and heavy-duty protection requirements. Feature: Power Xpert Protection Manager compatibility. Business Impact: Enables centralized protection management, trending, and maintenance planning, improving uptime and asset visibility. Application: Enterprise-wide electrical protection strategy in complex facilities.

Get a Quick Quote for a Eaton MPSC253VEAXX2H

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC253VEAXX2H? Enquire Now

FAQs

Yes. The MPSC253VEAXX2H features a fixed vertical mounting arrangement and a standard frame designed for easy integration into common low-voltage panels and motor control centers. Its three-pole construction and 16.2 in width fit typical industry enclosures, simplifying retrofit and new-install projects while maintaining robust protection for large feeders and motor circuits.
The PXR20 LSIAM electronic trip unit delivers advanced protection with precise current sensing, adjustable protection settings, and selective coordination capabilities. This reduces nuisance tripping, improves motor and feeder protection accuracy, and enables better integration with Protection Manager software for monitoring and maintenance, enhancing uptime in demanding industrial applications.
This breaker carries UL Listed and ANSI certifications, plus CE Marking and CSA certification, along with additional marks such as KEMA, Lloyd's Register, ABS, and DNV GL. These certifications support compliance across North America and Europe, helping you meet regulatory requirements for installations in diverse facilities.
The unit is rated for 2500 A continuous current with a 100 kA short-circuit interrupting rating. These ratings enable reliable protection for high‑current feeders and large motor loads, while supporting selective coordination strategies to minimize the impact of faults on nearby equipment.
Magnum PXR family breakers are ideal for main feeders, motor control centers, and critical process panels in manufacturing, chemical, and metals processing environments. With the PXR20 trip unit and Power Xpert compatibility, they support robust protection coordination, fast fault isolation, and centralized protection management across multi-site facilities.