Eaton Magnum low voltage power circuit breaker provides reliable fault protection for industrial power distribution. Operators and engineers struggle with downtime and unsafe maintenance when protection isn’t selective or easy to service. UL Listed, CE Marked, and NEMA compliant certifications ensure global compatibility and safety compliance across panels, plants, and marine applications. With Power Xpert Release trip units and motorized racking, it supports selective coordination and faster maintenance, delivering lower total cost of ownership. This makes it a strong fit for motor control centers and distribution panels where uptime matters. Engineers also gain integration comfort with Power Xpert Protection Manager for monitoring and coordination.
Product Information
Extended Description
MPSC303MEAXX2A Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 3000 A, 100 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSI trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC303MEAXX2A
UPC
786689637699
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
SABA Listed CE Marked NEMA Compliant CCC Marked
Certifications
KEMA Certified ANSI UL Listed Lloyd's Register Certified CSA Certified ABS Certified DNV GL Certified
Frame
Standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR20 LSI
Number of poles
Three-pole
Rated uninterrupted current (Iu)
3000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
3000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC303MEAXX2A
Eaton Specification Sheet - MPSC303MEAXX2A
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The MPSC303MEAXX2A combines a standard-frame Magnum PXR design with three poles and a drawout vertical mounting option that includes motorized racking. This feature reduces maintenance time and improves safety during breaker replacement or testing, which translates into higher plant availability and lower labor costs in switchgear applications. The Power Xpert Release (PXR20 LSI) trip unit delivers precise protection, enabling better selective coordination and reduced arc-energy exposure in motor control centers and panel boards. With a 3000 A Iu rating and a 100 kAIC interrupt capability, the device withstands heavy fault currents typical of large facilities, improving system reliability during short circuits and transient events. Its broad certification portfolio (UL Listed, CE Marked, NEMA Compliant, plus KEMA, CSA, ABS, and Lloyd’s Register) supports global project compliance and faster commissioning. The unit’s compatibility with Protective Management tools, including Power Xpert Protection Manager, enables remote monitoring and coordinated fault handling, reducing downtime and facilitating preventative maintenance strategies. Installation benefits include compatibility with standard breaker racks and existing buswork, plus straightforward field retrofit options for upgrading legacy protection without costly panel redesigns. In practice, the Magnum PXR trip unit supports zone-selective interlocking and selective protection schemes, which are essential for modern, energy-efficient distribution networks. This combination of features provides engineers with a practical path to improved reliability, safety, and lifecycle cost reduction in industrial facilities.
Get a Quick Quote for a Eaton MPSC303MEAXX2A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC303MEAXX2A?
Enquire Now
FAQs
The MPSC303MEAXX2A supports a drawout vertical mounting with motorized racking, designed for standard Magnum PXR frames. It fits typical switchgear and motor control centers, enabling safe, fast, and repeatable breaker replacements. Installation benefits include reduced maintenance time, easier testing, and compatibility with existing panel rails and buswork, which lowers retrofit costs and minimizes downtime.
Key specifications include a rated uninterrupted current (Iu) of 3000 A and an interrupt rating of 100 kAIC. It is a three-pole, standard-frame Magnum PXR with a PXR20 LSI trip unit. These ratings enable robust protection for large motors and feeders, supporting reliable operation in demanding industrial environments while enabling selective coordination.
Yes. Its three-pole, standard-frame design, motorized racking, and PXR20 LSI protection are well-suited for motor control centers and active distribution panels found in data centers and manufacturing facilities. The high interrupt rating and 3000 A Iu support reliable, safe switching and protection of critical loads, with easier maintenance and better coordination across feeds.
Projects should consider UL Listed, CE Marked, and NEMA compliance as baseline certifications. The unit also carries KEMA Certified, CSA Certified, ABS Certified, and Lloyd’s Register Certified markings, alongside additional compliance with ANSI and other global standards. This broad certification footprint helps teams meet local and international electrical safety and performance requirements.
The PXR20 LSI trip unit enables precise, coordinated protection, reducing nuisance trips and improving selectivity, which lowers fault-related downtime. Motorized racking speeds breaker maintenance and replacement, enhancing safety and minimizing labor costs. Overall, customers gain faster commissioning, lower energy losses from unnecessary trips, and a shorter path to compliant, reliable protection management with compatible monitoring tools.