Eaton MPSC303WEAXX2C Magnum LV Power Breaker - UL Listed
Part Number: MPSC303WEAXX2C
Quick Summary
The Eaton Magnum low voltage power circuit breaker MPSC303WEAXX2C provides reliable protection for industrial power distribution. Downtime during maintenance and part replacements can cost significant productivity; this unit’s drawout design minimizes disruption while enabling rapid servicing. The model carries UL Listed, CE Marked, and CSA Certified approvals, with Lloyd's Register recognition for broader global deployments. By integrating with Power Xpert Release trip units, it supports selective protection and remote monitoring, helping factories achieve higher availability and lower total cost of ownership. This combination suits standard-frame, three-pole installations in demanding production environments while delivering robust safety and compliance.
Product Information
Extended Description
MPSC303WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 3000 A, 100 kA, Three-pole, Drawout vertical mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC303WEAXX2C
UPC
786689636746
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
16.2 in
Product Weight
118 lb
Compliances
SABA Listed NEMA Compliant CCC Marked CE Marked
Certifications
Lloyd's Register Certified UL Listed CSA Certified KEMA Certified ANSI ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC303WEAXX2C
Eaton Specification Sheet - MPSC303WEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Feature: Three-pole, drawout vertical mounting provides safe, straightforward maintenance and fast circuit breaker replacement. Business Impact: Reduces downtime and risk during scheduled maintenance or fault isolation, improving line uptime. Application: Ideal for motor control centers and distribution panels in manufacturing facilities. Feature: Magnum PXR platform with LSIG trip unit enables precise protection tuning. Business Impact: Improves selectivity and fault isolation, lowering nuisance trips and energy waste. Application: Critical feeders and critical loads requiring coordinated protection. Feature: Power Xpert Release (PX R) compatibility supports remote protection management. Business Impact: Streamlines commissioning, enables remote diagnostics, and reduces on-site visits. Application: Large-scale automation lines and complex switchgear assemblies. Feature: Comprehensive certifications including UL Listed, CE Marked, CSA Certified, and Lloyd's Register. Business Impact: Simplifies global procurement, regulatory compliance, and cross-border projects. Application: Projects spanning multiple regions with strict safety and performance requirements. Feature: Standard frame, 3000 A rating, 100 kA interrupting capacity. Business Impact: Handles high fault currents and large motor starts without compromising protection. Application: Heavy industry power distribution and critical load centers. Feature: Drawout design and three-pole configuration support scalable installation. Business Impact: Enables modular upgrades and easier retrofits while maintaining alignment with existing enclosures. Application: OEM panels and retrofit projects in automation environments.
Get a Quick Quote for a Eaton MPSC303WEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC303WEAXX2C?
Enquire Now
FAQs
Installation begins with confirming panel compatibility for Magnum PXR devices, wiring to the three-pole bus and busbar stabs, and securing the unit in the standard frame with vertical drawout rails. Follow the MN013016en manual for step-by-step isolation, torque specs, and LSIG/trip unit integration. The drawout design speeds replacement and minimizes exposure during servicing.
The PX R release supports LSIG electronic protection, offering long-time and short-time protection with adjustable curves and coordination settings. This enables precise fault discrimination, reduced nuisance trips, and streamlined commissioning. For applications requiring motor protection and feeders, the LSIG option simplifies tuning while maintaining robust protection performance.
Yes. With a three-pole configuration, drawout mounting, and high interrupting capacity (100 kA), the breaker is well-suited for motor control centers and industrial switchgear. Certification coverage (UL Listed, CE Marked, CSA Certified) supports global deployments, while the rugged Magnum platform and PX R compatibility provide reliable protection across demanding environments.
The MPSC303WEAXX2C carries UL Listed, CE Marked, and CSA Certified approvals, plus Lloyd's Register certification. These attest to safety and performance per global standards, simplifying cross-border procurement, equipment acceptance by regulators, and conformity to NEC/NEMA requirements. For multi-region projects, these certifications reduce qualification time and regulatory risk.
Expect reduced downtime due to easier drawout maintenance, faster fault isolation from precise LSIG protection, and improved protection coordination with PX R integration. Remote monitoring and faster protection tuning further lower field service costs, shorten mean time to repair, and deliver a lower total cost of ownership for critical power systems.