Eaton MPSC304MEAXX2Q Magnum LV Power Breaker - UL Listed
Part Number: MPSC304MEAXX2Q
Quick Summary
Eaton Magnum low voltage power circuit breaker protects motor drives and distribution panels with proven overcurrent protection. Engineers often contend with long downtime, complex coordination, and difficult maintenance when upgrading protection schemes. This Magnum model delivers reliable, scalable protection in a four-pole frame with a 3000 A continuous rating and 100 kA interrupt capacity, engineered for fast, safe maintenance thanks to its drawout vertical design and motorized racking. It carries critical certifications for global deployment, including UL Listed, CSA Certified, and CE Marked, plus NEMA Compliant and CCC Marked compliance where required. For facilities pursuing continuous improvement and tighter coordination, this device pairs with Power Xpert Protection Manager and PX R trip units to improve visibility, alarm handling, and fault isolation while reducing total ownership costs.
Product Information
Extended Description
MPSC304MEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 3000 A, 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC304MEAXX2Q
UPC
786689633875
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
CCC Marked CE Marked SABA Listed NEMA Compliant
Certifications
CSA Certified Lloyd's Register Certified UL Listed KEMA Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC304MEAXX2Q
Eaton Specification Sheet - MPSC304MEAXX2Q
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Four-pole, 3000 A frame with a 100 kA interrupt rating. Business Impact: Withstands high fault currents and provides robust, reliable protection for large feeders and motor circuits. Application: Suitable for heavy-duty industrial panels and main distribution sections where high current interruption is critical. Feature: Drawout vertical mounting with motorized racking. Business Impact: Speeds breaker replacement, reduces live-front handling risk, and minimizes machine downtime. Application: Routine maintenance in manufacturing lines and data-center utility rooms where uptime matters. Feature: PXR25 LSIAM trip unit integration. Business Impact: Advanced electronic protection with precise trip coordination and fast fault isolation, improving reliability and safety. Application: Critical processes requiring selective coordination and rapid disconnection. Feature: Compact dimensions and weight (14.6 in depth, 16.8 in height, 21.2 in width, 160 lb). Business Impact: Easier deployment in standard switchgear cabinets and retrofit projects, saving space and installation time. Application: Retrofit and new-build panels in controlled environments. Feature: Global compliance (UL Listed, CSA Certified, CE Marked, NEMA Compliant, CCC Marked). Business Impact: Enables international installations with consistent safety and performance, reducing sourcing and qualification risk. Application: Multinational facilities and shared service centers. Feature: Ecosystem compatibility with Magnum and Power Xpert Protection Manager. Business Impact: Improved monitoring, fault logging, and remote configuration, delivering lower maintenance costs and quicker fault resolution. Application: Modern plant automation and facility-wide protection schemes.
Get a Quick Quote for a Eaton MPSC304MEAXX2Q
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC304MEAXX2Q?
Enquire Now
FAQs
This breaker uses a drawout vertical mounting with motorized racking, designed to fit standard Magnum enclosures and typical low-voltage switchgear footprints. Check panel opening width, busbar spacing, and internal clearance to ensure full travel of the racking mechanism. Weight and dimensional data (14.6 in depth, 16.8 in height, 21.2 in width; 160 lb) should align with cabinet ratings and mounting provisions to avoid interference with adjacent devices.
The PXR25 LSIAM trip unit provides advanced electronic protection with precise long-time, short-time, and instantaneous protection curves, enabling selective coordination across feeders. This supports tighter fault isolation, reduces nuisance trips, and aligns with modern protection schemes. When paired with Power Xpert Protection Manager, it also offers enhanced visibility, event logging, and remote configuration for complex industrial systems.
Yes. The MPSC304MEAXX2Q carries UL Listed and CSA Certified marks, plus CE Marked and NEMA Compliant status, with CCC Marked options as applicable. This broad certification suite supports international deployment across North America, Europe, and select markets, simplifying procurement, qualification, and cross-border maintenance for multinational facilities.
Motorized racking allows safe, quick removal and installation of the breaker without manual front-front handling or exposure to live parts in most configurations. This reduces maintenance time, lowers crew exposure to electrical hazards, and streamlines periodic replacement or testing cycles, delivering faster recovery after faults and easier scheduled maintenance in high-availability environments.
The upgrade delivers measurable ROI through reduced downtime from faster maintenance and safer retrofit operations, improved protective coordination with the PXR25 unit, and potential energy and fault-loss reductions from more precise protection. Global certification support also lowers lifecycle procurement friction for multi-site operations, while Power Xpert ecosystem compatibility enables proactive monitoring and informed maintenance planning.