Eaton MPSC304MEAXX2S Magnum LV Breaker - UL Listed
Part Number: MPSC304MEAXX2S
Quick Summary
Eaton Magnum low voltage power circuit breaker is a rugged protection device for critical electrical feeders in industrial power systems. When tripping and coordination reliability are on the line, field teams need a unit that resets quickly and coordinates with other protection schemes. It carries ANSI and UL listings, with CSA, KEMA, ABS and DNV GL certifications and CE marking for worldwide compliance. Designed for Magnum PXR protection, four poles, and motorized racking, this breaker delivers robust protection while simplifying maintenance and integration into modern protection architectures. For panel builders and integrators, the standard frame and drawout design streamline installation, service, and future upgrades.
Product Information
Extended Description
MPSC304MEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Standard frame, 3000 A, 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC304MEAXX2S
UPC
786689633882
Product Length/Depth
14.6 in
Product Height
16.8 in
Product Width
21.2 in
Product Weight
160 lb
Compliances
NEMA Compliant SABA Listed CCC Marked CE Marked
Certifications
ANSI Lloyd's Register Certified UL Listed CSA Certified KEMA Certified ABS Certified DNV GL Certified
Frame
Standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Standard
Series
Magnum
Trip Type
PXR25 LSIG ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
3000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
3000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC304MEAXX2S
Eaton Specification Sheet - MPSC304MEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Four-pole Magnum PXR standard-frame design with drawout vertical mounting and motorized racking enables safe, rapid maintenance and precise protection coordination in MCCs and panelboards, reducing downtime and service time. This translates to measurable uptime gains, easier changeovers, and smoother retrofits in complex distribution schemes. Rated uninterrupted current (Iu) of 3000 A and an interrupt rating of 100 kAIC provide headroom for high fault currents, improving system resilience and simplifying coordination studies for large facilities. The PXR25 LSIGAM ARMS trip unit delivers advanced protection curves and selective coordination, reducing nuisance trips while maintaining robust safety margins in high-demand environments. With multiple certifications and CE marking, the unit supports global deployment and regulatory compliance across diverse markets. The compact footprint (drawout, motorized racking, standard frame) and integration with Power Xpert Protection Manager streamline installation, commissioning, and ongoing protection monitoring for modern electrical infrastructures.
Get a Quick Quote for a Eaton MPSC304MEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC304MEAXX2S?
Enquire Now
FAQs
The MPSC304MEAXX2S is designed for industrial power distribution, including motor control centers, distribution panels, and large switchgear. Its four-pole Magnum PXR design and 3000 A Iu rating support high-demand feeders, while the 100 kAIC interrupt capacity protects essential circuits from fault currents. This makes it ideal for manufacturing lines, data centers, and processing plants where reliability and selectivity are critical.
The PXR25 LSIGAM trip unit provides advanced protection logic with LRMS-style tripping characteristics and ARMS coordination to minimize nuisance trips while preserving safety. It enables precise long-time, short-time, and instantaneous protection settings, improving selectivity between upstream and downstream devices. This results in better fault isolation, reduced downtime, and easier compliance with protection standards in complex electrical networks.
Yes. With four-pole, standard-frame construction and motorized racking, the MPSC304MEAXX2S is optimized for MCCs and panel boards. The motorized racking simplifies maintenance and swapping of units, while the high current rating and 100 kAIC interrupt capacity support reliable motor protection and feeder safeguarding in demanding applications such as conveyors, pumps, and processing lines.
This breaker carries ANSI and UL listings, CSA, KEMA, ABS, and DNV GL certifications, along with CE marking and NEMA compliance. These qualifications support global product acceptance, ease audits, and help meet international electrical codes and standards for marketplaces in North America, Europe, and beyond.
Maintenance benefits include safer, faster servicing thanks to motorized racking and a drawout design, plus easier replacement and upgrade paths in protection architectures. ROI is driven by reduced downtime from improved protection coordination, lower risk of nuisance trips, and streamlined monitoring through Power Xpert Protection Manager integration, which enables proactive maintenance and faster fault diagnosis.