Eaton MPSC404MEAXX2Q Magnum LV Breaker - UL Listed 100 kA
Part Number: MPSC404MEAXX2Q
Quick Summary
The Eaton Magnum low voltage power circuit breaker is designed to protect motors and feeders in demanding industrial plants. Engineers often wrestle with coordinating protection and minimizing downtime during maintenance, and the drawout vertical design with motorized racking helps reduce effort and risk. The unit carries UL Listed and CE Marked certifications, with NEMA compliance and global listings such as SABA, ANSI, CSA, Lloyd's Register, ABS and DNV GL for broad applicability. With a Power Xpert Release trip unit (PXR25 LSIAM), four-pole construction, and a 100 kA short-circuit rating, this solution supports scalable protection and safer, faster maintenance across panels. This combination aligns with plant-wide protection strategies and ongoing lifecycle cost reduction.
Product Information
Extended Description
MPSC404MEAXX2Q Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (NNABCABC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC404MEAXX2Q
UPC
786689633301
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CCC Marked CE Marked SABA Listed
Certifications
KEMA Certified ANSI CSA Certified Lloyd's Register Certified UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC404MEAXX2Q
Eaton Specification Sheet - MPSC404MEAXX2Q
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Four-pole Magnum PXR frame with a 100 kA short-circuit rating enables robust protection for large motor loads. Business Impact: Reduces electrical incidents and unplanned downtime, improving line uptime and safety. Application: Ideal for motor control centers and distribution panels in heavy manufacturing. Feature: Drawout vertical mounting with motorized racking enables rapid, safe breaker replacement. Business Impact: Minimizes maintenance time and exposure to live equipment, lowering labor costs. Application: Retrofit and upgrade projects in existing switchgear. Feature: Power Xpert Release (PXR) LSIAM trip unit provides precise protection coordination and adjustable trip curves. Business Impact: Improves selective tripping, energy management, and compliance reporting. Application: Process industries requiring tight protection coordination. Feature: Large-form factor with defined dimensions and weight (16.3 in depth, 16.8 in height, 44.1 in width, 319 lb). Business Impact: Ensures compatibility with standard cabinets and supports mechanical interlocks. Application: New builds and replacements in space-constrained panels. Feature: Extensive certifications and compliance (NEMA, CE, UL Listed, ANSI, CSA, KEMA, Lloyd's Register, ABS, DNV GL). Business Impact: Enables global deployment and reduces regulatory risk. Application: Global plants and multi-site installations. Feature: Zone selective interlocking capability documented in Eaton resources and compatible with Magnum PxR ecosystems. Business Impact: Fault isolation improves safety and reduces fault clearance time. Application: Critical power systems requiring fast isolation. Insight: Real-world installations benefit from combining motorized racking with protection-management tools like Power Xpert Protection Manager for centralized monitoring and diagnostics.
Get a Quick Quote for a Eaton MPSC404MEAXX2Q
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC404MEAXX2Q?
Enquire Now
FAQs
The MPSC404MEAXX2Q uses a drawout vertical mounting with motorized racking, designed for Magnum PXR-based switchgear. It fits standard low-voltage panels and motor control centers requiring a four-pole, high-availability breaker with protection coordination. Ensure mounting rails and bus connections comply with the 44.1 in width and 16.8 in height footprint, and verify alignment with the PXR25 LSIAM trip unit for correct trip curve selection.
Key ratings include four poles and a 100 kA short-circuit rating with a 4000 A frame. The PXR25 LSIAM trip unit provides advanced protection characteristics and adjustable trip curves for precise coordination. Time-current curves, maintenance diagnostics, and protection settings can be reviewed via Eaton’s documentation and the Power Xpert Protection Manager for improved reliability and reporting.
Ideal for heavy motor loads in manufacturing, process industries, and power distribution panels. It supports safe maintenance with motorized racking and zone selective interlocking documentation, making it suitable for large motor control centers, packaging lines, and metal/plastics processing plants where uptime and protection coordination are critical.
The MPSC404MEAXX2Q is UL Listed and CE Marked, with NEMA compliance and SABA listing. It also carries ANSI, CSA, Lloyd's Register, ABS, DNV GL, and KEMA certifications, ensuring global acceptance and regulatory alignment across multi-site installations.
Motorized racking reduces maintenance time and exposure to live equipment, while the PXR trip unit improves protection coordination, potentially reducing spare-part and downtime costs. Downloads and manuals, such as protection manager guides and zone selective interlocking papers, support ongoing optimization and faster troubleshooting across sites.