Eaton MPSC4A4MEAXX2H Magnum low-voltage breaker - UL

Part Number: MPSC4A4MEAXX2H
Manufacturer
Eaton
Part number
MPSC4A4MEAXX2H

Quick Summary

The Eaton Magnum low-voltage power circuit breaker delivers reliable overcurrent protection for industrial power distribution panels. For engineers and procurement teams, improper coordination can cause nuisance trips, downtime, and escalating maintenance costs. This unit carries CE Mark and UL Listed status, with SABA Listed and ANSI certifications supporting regional compliance; Lloyd's Register and CSA approvals further enable global projects. With four poles, a drawout vertical design, motorized racking mounting, and a Power Xpert Release trip unit, it improves coordination, reduces service interruptions, and simplifies retrofits in demanding environments. The device aligns with industry standards while delivering measurable efficiency and total cost of ownership benefits.

Product Information

Extended Description

MPSC4A4MEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (NABCNABC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC4A4MEAXX2H
UPC
786689634308
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CE Marked CCC Marked SABA Listed
Certifications
Lloyd's Register Certified UL Listed ANSI KEMA Certified CSA Certified ABS Certified DNV GL Certified
Feature: High fault current capability up to 4000 A and 100 kA short-circuit rating. Business Impact: Protects critical feeders against catastrophic faults, reducing equipment damage and downtime; Application: large motor feeders and distribution panels in manufacturing and data centers. Feature: Drawout vertical mounting with motorized racking. Business Impact: Speeds maintenance and replacements while minimizing operator exposure; Application: switchgear rooms and control panels with frequent maintenance cycles. Feature: Four-pole configuration with PXR20 LSIAM trip unit. Business Impact: Enhanced phase coordination and precise protection, lowering nuisance trips and improving reliability; Application: complex three-phase systems and multi-motor layouts. Feature: Power Xpert Release trip unit integration. Business Impact: Fast, selective tripping and improved protection coordination across the plant; Application: critical process lines and energy-intensive equipment. Feature: Broad certifications including CE, UL Listed, ANSI, CSA, KEMA, Lloyd's Register, ABS, DNV GL. Business Impact: Enables global deployment with regulatory confidence; Application: multinational projects and cross-regional rollouts. Feature: Zone selective interlocking (ZSI) readiness via application notes. Business Impact: Accelerates fault isolation and minimizes impact on healthy feeders; Application: large factories with dense feeder networks. Feature: Compatibility with protection management tooling. Business Impact: Enables remote monitoring, analysis, and preventative maintenance; Application: plants leveraging Power Xpert Protection Manager for enterprise-wide protection strategies.

Get a Quick Quote for a Eaton MPSC4A4MEAXX2H

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC4A4MEAXX2H? Enquire Now

FAQs

Install the four-pole, drawout breaker into a suitably rated low-voltage panel designed for 4000 A and 100 kA fault current. Use the vertical drawout mechanism with the motorized racking to engage and withdraw the unit safely, following the manufacturer's interlock procedures. Ensure the Protection Unit (PXR20 LS IAM) is configured for the system and verify control wiring, alignment, and panel clearance to prevent arcing or mis-trips.
The PXR20 LSIAM trip unit provides advanced protection logic with adjustable, state-specific curves and instantaneous trip settings to optimize coordination along the feeder chain. This reduces unnecessary trips on non-fault alarms and limits arc energy exposure. It is particularly beneficial for motor feeders and multi-load buses where precise selectivity minimizes downtime while preserving protection integrity.
Yes. With a 4000 A rating and 100 kA short-circuit capability, four-pole configuration, and motorized racking, it suits high-energy manufacturing lines and data center feeders requiring robust protection and rapid, reliable switching. Its PXR20/LUIs trip unit supports selective coordination across complex power architectures, helping maintain uptime and protect valuable equipment under fault conditions.
The MPSC4A4MEAXX2H carries UL Listed and CE Marked status, along with SABA listing and ANSI, CSA certifications. Additional approvals include Lloyd's Register, KEMA, ABS, and DNV GL, enabling confident deployment in diverse regions and stricter regulatory environments. Always verify local requirements to ensure full conformity for your installation site.
Investing in the Magnum breaker with motorized racking and a PXR20 trip unit reduces maintenance labor through faster drawout operations and safer, simpler maintenance cycles. The enhanced protection coordination lowers unexpected downtime, while widely recognized certifications simplify vendor qualification across sites. Access to technical papers and protection software also supports proactive maintenance and lifecycle planning.