Eaton MPSC4A4WEAXX2H Magnum LV Breaker - PXR20 LSIAM
Part Number: MPSC4A4WEAXX2H
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial power distribution cabinets with robust protection. In demanding facilities, nuisance trips and poor coordination can throttle uptime and complicate maintenance. UL Listed, CE Marked, and CSA Certified provide broad regulatory compliance, while the PXR20 LSIAM trip unit delivers precise protection and selective coordination. Designed for double-frame, drawout vertical mounting, it integrates with Power Xpert Protection Manager for monitoring, control, and fault diagnostics—helping engineering teams reduce downtime and extend panel lifespan.
Product Information
Extended Description
MPSC4A4WEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 4000 A (NABCNABC), 100 kA, Four-pole, Drawout vertical mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC4A4WEAXX2H
UPC
786689634926
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CCC Marked NEMA Compliant SABA Listed CE Marked
Certifications
CSA Certified ANSI Lloyd's Register Certified UL Listed KEMA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC4A4WEAXX2H
Eaton Specification Sheet - MPSC4A4WEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The four-pole design with a 4000 A interrupt rating and 100 kA short-circuit rating delivers robust feeder protection and enables selective coordination, reducing downstream damage in large motor circuits and critical feeders. This translates to fewer nuisance trips and shorter repair times in MCCs and process lines. The PXR20 LSIAM trip unit provides advanced protection logic for fast, accurate tripping and easier fault diagnostics, improving overall system reliability and maintenance planning. Drawout vertical mounting simplifies installation and replacement, minimizing outage duration during panel upgrades or retrofits in existing switchgear. Double-frame Magnum compatibility reduces spare parts variety and procurement effort for multi-bay installations across manufacturing plants. Integration with Power Xpert Protection Manager enables remote monitoring, event logging, and coordinated protection strategies that support predictive maintenance and asset optimization. All-round certifications and global compliance support cross-border deployments with confidence.
Get a Quick Quote for a Eaton MPSC4A4WEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC4A4WEAXX2H?
Enquire Now
FAQs
Yes. The breaker employs a drawout vertical mounting within a double-frame Magnum design, a common configuration in low-voltage panels and motor control centers. When retrofitting, verify frame size, mounting dimensions, and panel throat clearance against Eaton catalogs to ensure proper fit and safe operation.
The unit is a four-pole breaker with a 4000 A interrupt rating (NABCNABC) and a 100 kA short-circuit current rating. Catalog number MPSC4A4WEAXX2H, UL Listed, and CE Marked, with a PXR20 LSIAM trip unit for precise protection and coordination in demanding applications.
Absolutely. Its four-pole configuration, high SCCR, and Power Xpert compatibility make it ideal for motor control centers and critical process lines where reliable protection, coordination, and diagnostic visibility are essential for uptime and safety.
The product carries UL Listed, CE Marked, and CSA Certified status, along with ANSI, Lloyd’s Register, KEMA, DNV GL, and ABS certifications, enabling compliant deployments in North America, Europe, and other regions.
Magnum PXR enables reduced downtime through accurate tripping and easier fault diagnosis, while remote monitoring with Power Xpert Protection Manager supports predictive maintenance. Availability of renewal parts and accessories further lowers total cost of ownership over the equipment lifecycle.