Eaton MPSC503MEAXX2F Magnum low voltage power circuit breaker - 100 kAIC
Part Number: MPSC503MEAXX2F
Quick Summary
Eaton Magnum low voltage power circuit breaker protects critical electrical systems in industrial facilities. Operators face nuisance trips, costly downtime, and challenging motorized racking during protection upgrades. UL Listed, CE Marked, and CSA Certified components underpin compliance across global projects, with additional Lloyd's Register references in high-risk sectors. This solution also integrates with modern protection ecosystems, offering easy maintenance and scalable protection coordination for expanding plant networks.
Product Information
Extended Description
MPSC503MEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 100 kA, Three-pole, Drawout vertical with motorized racking mounting, PXR20 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC503MEAXX2F
UPC
786689635299
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked CCC Marked SABA Listed NEMA Compliant
Certifications
UL Listed KEMA Certified CSA Certified Lloyd's Register Certified ANSI DNV GL Certified ABS Certified
Frame
Double standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR20 LSIG ARMS
Number of poles
Three-pole
Rated uninterrupted current (Iu)
5000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
5000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC503MEAXX2F
Eaton Specification Sheet - MPSC503MEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The Magnum PXR trip unit with LSIG ARMS delivers precise, selective protection, reducing nuisance outages and extending equipment life for motor feeders and main circuits. Business impact: lower downtime and reduced arc energy exposure, enabling safer, faster commissioning and easier fault analysis in panels and switchgear. Application: data centers, manufacturing lines, and process plants where dependable interrupt performance is mission-critical. The drawout vertical mounting with motorized racking simplifies maintenance and component swaps, cutting service time and improving uptime metrics. The double standard frame, three-pole construction, and 5000 A Iu rating support large feeders while maintaining compact footprint, improving space utilization. Compatibility with Power Xpert Protection Manager enables remote monitoring, event logging, and faster fault resolution, boosting overall asset intelligence. Zone selective interlocking notes provide enhanced coordination, improving selective tripping and reducing system-wide outages in complex electrical rooms. Industry insight: technicians appreciate standardized accessories and renewal parts to minimize spares inventory and downtime during retrofits.
Get a Quick Quote for a Eaton MPSC503MEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC503MEAXX2F?
Enquire Now
FAQs
The MPSC503MEAXX2F uses a drawout vertical mounting approach with a motorized racking system, compatible with Magnum PXR frames and three-pole configurations. Ensure panel space accommodates a double standard frame up to 31.1 in wide and 16.3 in deep, with proper bus connections and torque per Eaton guidance. Verify LSIG ARMS trip module compatibility and confirm panel clearance for maintenance.
Key ratings include rated uninterrupted current Iu = 5000 A and an interrupt rating of 100 kAIC, with a three-pole, drawout construction and PXR20 LSIG ARMS trip unit. The device supports zone selective interlocking and is designed for reliable protection in heavy-duty motor feeders and main distributions, meeting stringent industry standards.
Ideal for industrial facilities, manufacturing lines, and data centers where high fault current protection, selective coordination, and reliable motor protection are essential. The Magnum PXR with LSIG ARMS is well-suited for main and feeder protection in large switchgear, where uptime, safety, and accurate fault isolation drive operating efficiency.
This breaker is UL Listed, CE Marked, and CSA Certified, with additional approvals referenced for global applicability. Compliance support helps streamline procurement and installation in regulated environments, while the UL and CSA certifications assist with end-user safety documentation and maintenance planning.
The motorized racking and drawout design minimize replacement time and field downtime, while Power Xpert Protection Manager compatibility enables proactive monitoring, event analysis, and streamlined servicing. The combination reduces maintenance costs, improves mean time to repair (MTTR), and enhances protection coordination across large electrical networks.