Eaton MPSC503MEAXXSW Magnum Breaker - UL Listed
Part Number: MPSC503MEAXXSW
Quick Summary
Eaton Magnum low-voltage power circuit breaker protects distribution panels and machines with reliable arc quenching. Engineers often battle downtime during maintenance and struggle with protection coordination across feeders, which the drawout vertical design and motorized racking help mitigate. This unit carries UL Listed and CE marked certifications, along with ANSI and NEMA compliance, ensuring safe, regulatory-compliant operation in North American and international installations. By standardizing on Magnum protection, you gain a scalable platform that aligns with Power Xpert tools and simplifies service planning, stocking, and lifecycle costs for mission-critical applications.
Product Information
Extended Description
MPSC503MEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 100 kA, Three-pole, Drawout vertical with motorized racking mounting, No trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC503MEAXXSW
UPC
786689635145
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CCC Marked CE Marked NEMA Compliant SABA Listed
Certifications
ANSI KEMA Certified Lloyd's Register Certified CSA Certified UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC503MEAXXSW
Eaton Specification Sheet - MPSC503MEAXXSW
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Drawout vertical with motorized racking enables safe, rapid breaker replacement during commissioning or maintenance, reducing arc-flash exposure and downtime. In panel designs, this compatibility supports hot-swapping without full-system shutdown, accelerating project timelines and lowering maintenance costs. Three-pole construction with a 5000 A interrupting capacity (ABCABC) and a 100 kA short-circuit rating delivers robust protection for feeders and motors, improving uptime in heavy-usage environments and reducing fault-related damage. The no trip unit configuration simplifies procurement and minimizes upfront costs while still enabling coordination with Magnum PXR protection if future upgrades are pursued. The compact yet substantial footprint (16.3 in L, 16.8 in H, 31.1 in W) and a 237 lb weight enable integration into standard switchgear racks, reducing design concessions and enclosure complexity. Global compliance is built in through UL Listed, CE marked, ANSI, and NEMA certifications, supporting international projects. Although shipped without a trip unit, it remains compatible with Power Xpert Release units for advanced coordination, giving users a clear migration path as protection needs evolve.
Get a Quick Quote for a Eaton MPSC503MEAXXSW
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC503MEAXXSW?
Enquire Now
FAQs
Installers should ensure vertical drawout mounting space within standard enclosures, verify clearance for motorized racking operation, and confirm alignment with panelbus stabs. Allow for service clearances on both sides to enable safe rack-and-replace procedures and cable management within the enclosure.
It is a three-pole device with a 5000 A interrupting capacity (ABCABC) and a 100 kA short-circuit rating, suitable for heavy feeders and motor circuits in demanding industrial environments. The unit ships without a trip unit, enabling tailored coordination with compatible protection modules if desired.
Yes. The breaker carries UL Listed and CE marked certifications, and complies with ANSI and NEMA requirements, supporting usage in globally regulated panel assemblies and equipment builds.
The current unit ships without a trip unit, but it is compatible with Magnum PXR protection units. This provides a pathway to advanced coordination and protection upgrades without replacing the breaker housing.
Motorized racking supports safer, faster breaker removal and installation, reducing exposure to live parts during maintenance. It enables efficient hot-swapping and simplified maintenance planning, which translates to lower downtime and improved overall equipment effectiveness.