Eaton MPSC503WEAXX2C Magnum LV Breaker - UL Listed
Part Number: MPSC503WEAXX2C
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial power distribution in machinery and facilities. Maintenance teams often face nuisance trips and downtime, making reliability and easy service a top priority. It carries UL Listed, CSA Certified, and CE Marked approvals, with additional NEMA compliance for global installations. Coupled with a PXR20 LSIG trip unit and Power Xpert readiness, this solution supports scalable protection schemes while reducing lifecycle costs.
Product Information
Extended Description
MPSC503WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 100 kA, Three-pole, Drawout vertical mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC503WEAXX2C
UPC
786689630898
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CCC Marked CE Marked SABA Listed NEMA Compliant
Certifications
CSA Certified Lloyd's Register Certified KEMA Certified ANSI UL Listed ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC503WEAXX2C
Eaton Specification Sheet - MPSC503WEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The PXR20 LSIG trip unit delivers precise overload and short-circuit protection with selective coordination, reducing nuisance trips and arc-flash energy while improving personnel safety. This configuration supports motor feeders and process lines in manufacturing environments, where reliable protection directly translates to higher uptime and lower maintenance costs. The drawout vertical mounting and three-pole frame simplify installation, replacement, and routine maintenance in complex switchgear assemblies, shortening downtime during retrofits and new builds. With a short-circuit rating of 5000 A (ABCABC) and an interrupting capacity of 100 kA, it provides robust fault handling for high-current systems, enabling safer operation of large motors and drives and better upstream coordination. The compact footprint—16.3 in depth, 16.8 in height, and 31.1 in width—combined with a 237 lb weight supports stable, service-friendly integration in MCCs and panel boards. Compliance across UL, CSA, CE, and NEMA standards ensures global applicability, while compatibility with Power Xpert Protection Manager enables remote monitoring and protection management for reduced total cost of ownership. This combination addresses common objections about retrofits, delivering a solution that scales with evolving protection schemes and factory automation needs.
Get a Quick Quote for a Eaton MPSC503WEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC503WEAXX2C?
Enquire Now
FAQs
The MPSC503WEAXX2C is a three-pole Magnum low-voltage breaker with a drawout vertical mounting design and a PXR20 LSIG trip unit. It is compatible with Magnum switchgear and supports Power Xpert Protection Manager workflows, making retrofits and new installations straightforward without needing major panel redesigns.
This unit provides a 5000 A withstand (ABCABC) and a 100 kA interrupting capacity, three-pole configuration, and PXR20 LSIG protection. It is designed for selective coordination with upstream devices in motor feeders and distribution networks, reducing nuisance trips while maintaining strong fault protection for high-current applications.
Yes. The three-pole drawout Magnum breaker with PXR20 LSIG and robust interrupting capacity is ideal for motor control centers, process lines, and distribution panels found in manufacturing and process industries. Its compatibility with Power Xpert tools helps optimize motor protection schemes and streamline commissioning and maintenance.
The MPSC503WEAXX2C carries UL Listed, CSA Certified, and CE Marked approvals, along with NEMA compliance for global installations. Additional certifications include KEMA, Lloyd's Register, ABS, DNV GL, and ANSI. This breadth supports diverse regulatory environments and customer requirements across regions.
Eaton provides comprehensive resources, including quick-start guides, manuals, and application papers. Downloads cover zone selective interlocking, selective coordination, and Power Xpert Protection Manager software, supporting fast commissioning, protection configuration, and ongoing maintenance in complex electrical installations.