Eaton MPSC503WEAXXSW Magnum LV Breaker - UL Listed
Part Number: MPSC503WEAXXSW
Quick Summary
The Eaton Magnum low voltage power circuit breaker protects critical distribution in industrial facilities. Engineers often struggle to keep feeders safeguarded without sacrificing maintenance speed or uptime. UL Listed, ANSI, and Lloyd's Register certifications provide regulatory assurance for global installations, with additional KEMA, CSA, and ABS recognition supporting cross-border use. This three-pole, drawout vertical-mount device ships without a trip unit, enabling straightforward integration with Magnum PXR trip units when upgrading protection suites. For panel builders and plant engineers, this translates to faster commissioning, reduced spare parts, and improved reliability, while aligning with Power Xpert Protection Manager workflows for coordinated protection and monitoring.
Product Information
Extended Description
MPSC503WEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (ABCABC), 100 kA, Three-pole, Drawout vertical mounting, No trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC503WEAXXSW
UPC
786689630874
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
NEMA Compliant CE Marked SABA Listed CCC Marked
Certifications
UL Listed ANSI Lloyd's Register Certified KEMA Certified CSA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC503WEAXXSW
Eaton Specification Sheet - MPSC503WEAXXSW
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The MPSC503WEAXXSW offers drawout vertical mounting with no trip unit, reducing upfront wiring complexity and enabling quick field upgrades when protection needs evolve. Business impact: faster installation, lower initial costs, and streamlined maintenance in panel assemblies for power distribution lines in manufacturing and processing plants. Application: best suited for control panels and switchgear in environments where future protection upgrades are anticipated, such as automotive, food and beverage, or chemical processing facilities. The three-pole design and robust frame support high fault currents while preserving safe disconnection sequences, improving system reliability and reducing downtime during fault events. This unit’s compatibility with Magnum PXR trip units and the Power Xpert Protection Manager ecosystem enables coordinated protection, diagnostics, and easier asset management. Long-tail keywords addressed include low voltage circuit breaker for industrial panels, three-pole LV breaker, and drawout vertical mounting requirements for panel builders. Additional advantages include UL Listed and ANSI/CE compliant design, which accelerates procurement approvals and cross-border installations, while supporting regulatory compliance and risk mitigation across global sites. The device’s 5000 A frame capability and 100 kA short-circuit rating provide robust protection for feeders feeding critical loads, helping facilities avoid costly equipment damage and unplanned downtime. The product’s dimensions and weight—16.3 in depth, 16.8 in height, 31.1 in width, and 237 lb—facilitate precise space planning in new or retrofit projects and support rigid installation tolerances in dense switchgear environments. Industry insights show that modular, upgrade-friendly breakers reduce total cost of ownership by enabling staged protection enhancements without large equipment replacements.
Get a Quick Quote for a Eaton MPSC503WEAXXSW
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC503WEAXXSW?
Enquire Now
FAQs
This breaker uses a three-pole, drawout vertical mounting design and ships without a trip unit, allowing straightforward field upgrades. It is compatible with Magnum PXR trip units and supports integration within the Power Xpert Protection Manager environment, enabling coordinated protection and diagnostic workflows in new installations or retrofit projects.
The MPSC503WEAXXSW is built for high-demand protection with a 5000 A frame and 100 kA short-circuit current capability. It is designed as a three-pole device suitable for industrial feeders, offering robust protection while accommodating field upgrading with compatible trip units when needed.
Yes. This unit carries UL Listed status and ANSI certifications, with additional CE Marking and Lloyd's Register recognition. Such certifications support global installations, simplify procurement approvals, and help ensure compliance with safety, performance, and quality standards across international sites.
Absolutely. While the MPSC503WEAXXSW ships without a trip unit, it is designed to be compatible with Magnum PXR trip units and Power Xpert Protection Manager workflows, enabling coordinated protection, monitoring, and management within modern protection architectures.
The drawout design and upgrade-friendly trip-unit integration reduce maintenance downtime and spare-parts inventory. UL/ANSI/CE certifications support long-term reliability and regulatory alignment, while the rugged Magnum construction minimizes replacement cycles in harsh industrial environments, delivering measurable ROI through reduced downtime and faster service actions.