Eaton MPSC504VEAXX2S Magnum low voltage power circuit breaker - UL Listed 100 kA

Part Number: MPSC504VEAXX2S
Manufacturer
Eaton
Part number
MPSC504VEAXX2S

Quick Summary

The Eaton Magnum low voltage power circuit breaker protects critical feeders in industrial automation and power distribution. Facing unexpected trips and downtime, engineers need a solution that combines precise protection with straightforward integration. It carries CE Marked, UL Listed, and CSA Certified approvals, plus NEMA compliance for rugged environments. With Power Xpert Release trip units and Protection Manager integration, it offers reliable protection, easier maintenance, and lower life-cycle costs. This combination supports safer operation, optimized asset health, and scalable protection across multiple sites.

Product Information

Extended Description

MPSC504VEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNABCABC), 100 kA, Four-pole, Fixed vertical mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC504VEAXX2S
UPC
786689631147
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked SABA Listed CCC Marked NEMA Compliant
Certifications
CSA Certified ANSI Lloyd's Register Certified KEMA Certified UL Listed DNV GL Certified ABS Certified
Feature: Four-pole Magnum frame provides robust, balanced protection for large feeders. Business Impact: This topology improves fault current distribution, reduces dV/dt stress, and minimizes arc flash exposure. Application: Ideal for motor feeders, MCCs, and critical panels in manufacturing and process plants. Feature: Fixed vertical mounting simplifies installation in compact switchgear and control cabinets. Business Impact: It minimizes required space, speeds commissioning, and lowers assembly errors during field upgrades. Application: Fits standard electrical rooms in automotive, food & beverage, and packaging lines. Feature: PXR25 LSIGAM electronic trip unit delivers precise protection curves and cooperative settings. Business Impact: Enhanced selectivity reduces nuisance trips while improving upstream coordination and diagnostic visibility. Application: Suitable for systems demanding tight protection coordination across feeders and motors. Feature: High interrupting capacity of 100 kA covers demanding fault conditions. Business Impact: Enables safe clearance of large faults and protects downstream equipment from cascading damage. Application: Data centers, heavy machinery, and large motor installations. Feature: Global certifications including CE, UL Listed, CSA Certified, and NEMA compliance. Business Impact: Facilitates multi‑region deployments, simplifies procurement, and supports regulatory audits. Application: Projects requiring international standards across North America and Europe. Feature: Rich supporting documentation and Eaton resources such as spec sheets and application papers. Business Impact: Streamlines engineering specs, accelerates validation, and supports maintenance planning. Application: Engineering design, installation QA, and predictive maintenance programs. Feature: Power Xpert Protection Manager readiness with the Magnum PXR trip unit. Business Impact: Centralized protection management, remote diagnostics, and faster MTTR during faults. Application: Control rooms and OEM integrations needing reliable monitoring across the plant.

Get a Quick Quote for a Eaton MPSC504VEAXX2S

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC504VEAXX2S? Enquire Now

FAQs

MPSC504VEAXX2S uses fixed vertical mounting designed for panel integration. The unit occupies a substantial footprint suitable for standard power distribution cabinets; ensure mounting rails and bolting patterns align with the four-pole frame and that there is adequate space for service clearances and wiring access as per site standards.
This model is CE Marked, UL Listed, and CSA Certified, with additional NEMA compliance. These certifications indicate conformity with European, North American, and national safety and performance standards, facilitating global procurement, regulatory audits, and cross-border deployments.
The breaker features four poles, an interrupting capacity of 100 kA, frame rating of 5000 A, and a PXR25 LSIGAM electronic trip unit. The catalog number is MPSC504VEAXX2S, with dimensions approximately 16.3 in L, 16.8 in H, and 44.1 in W, and a weight around 319 lb.
Yes. The Magnum MPSC504VEAXX2S is designed to work with Power Xpert Protection Manager and the PXR trip units, enabling centralized protection management, real-time diagnostics, and streamlined maintenance workflows.
It is ideal for motor feeders, motor control centers, data centers, and large manufacturing lines where high fault current, precise protection, and global compliance are required. It supports rigorous protection coordination and is suitable for both new builds and retrofit projects.