Eaton MPSC504VEAXXSW Magnum LV Circuit Breaker - UL Listed
Part Number: MPSC504VEAXXSW
Quick Summary
Eaton Magnum low voltage power circuit breaker protects electrical systems by interrupting fault currents in industrial power distribution. Sizing the right frame, trip unit options, and mounting orientation can slow procurement and commissioning. This model carries UL Listed, CE Marked, and Lloyd's Register certifications, with CSA certification among others, supporting safety, reliability, and regulatory compliance. Designed as a four-pole base frame with fixed vertical mounting, it can be configured with Power Xpert Release trip units when required, delivering scalable protection for panel builders and OEMs while simplifying installation.
Product Information
Extended Description
MPSC504VEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNABCABC), 100 kA, Four-pole, Fixed vertical mounting, No trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC504VEAXXSW
UPC
786689631086
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant SABA Listed CE Marked CCC Marked
Certifications
Lloyd's Register Certified KEMA Certified CSA Certified ANSI UL Listed DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC504VEAXXSW
Eaton Specification Sheet - MPSC504VEAXXSW
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
High interrupting capacity and robust frame design enable reliable protection for large feeders and motors, with a 5000 A rating (NNABCABC) and 100 kA short-circuit capacity. Business impact: reduced risk of equipment damage and downtime; application: main distribution panels and motor feeders. Four-pole construction with fixed vertical mounting simplifies panel integration, reduces installation time, and improves fault isolation in compact switchgear environments. Business impact: faster commissioning, easier maintenance, and improved space utilization; application: panelboards and enclosures with limited depth. No trip unit is included, offering a flexible upgrade path to Power Xpert Release trip units when needed, enabling scalable protection without replacing the base frame. Business impact: lowers upfront cost while preserving upgrade options; application: OEM and retrofit projects. The product carries broad certifications and compliance marks, including NEMA, CE, and UL listings, reducing regulatory risk and accelerating customer acceptance. Business impact: smoother audits and faster market access; application: global deployments. With a weight of 319 lb and dimensions of 16.3 in depth, 16.8 in height, and 44.1 in width, the Magnum MPSC504VEAXXSW is built for sturdy, long-life operation in demanding environments. Business impact: durable performance with predictable lifecycle costs; application: industrial facilities, data centers, and manufacturing lines. Compatibility with the Magnum PXR ecosystem and available coordination literature support zone selective interlocking and selective coordination strategies for optimized reliability and safety.
Get a Quick Quote for a Eaton MPSC504VEAXXSW
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC504VEAXXSW?
Enquire Now
FAQs
MPSC504VEAXXSW uses a four-pole fixed vertical mounting frame, designed for straightforward integration into standard low-voltage panels. It ships without a trip unit, enabling a tailored protection scheme. For enhanced protection, it can be equipped with Power Xpert Release trip units later, allowing a scalable upgrade path without replacing the frame. This simplifies retrofits and OEM panel design while delivering reliable fault interruption.
This model is a four-pole, low-voltage circuit breaker with a 5000 A rating (NNABCABC) and a 100 kA short-circuit capacity. It weighs 319 lb and measures 16.3 in in depth, 16.8 in in height, and 44.1 in in width. Catalog Number is MPSC504VEAXXSW, and it carries UL Listed, CE Marked, and multiple international certifications for safe, compliant operation.
Yes, it supports selective coordination strategies when used with Power Xpert Release trip units. The base frame is designed for easy upstream coordination, and Eaton provides guidance on zone selective interlocking and selective coordination in relevant application papers. For retrofit projects, you can upgrade with a release trip unit to achieve finer coordination without replacing the frame.
The MPSC504VEAXXSW carries NEMA compliance, SABA listing, CE Mark, CCC Mark, and UL Listing, along with certifications from Lloyd's Register, KEMA, CSA, ANSI, DNV GL, and ABS. These validations indicate broad safety, performance, and regulatory acceptance across North America, Europe, and other regions, reducing certification risk for global deployments.
The unit’s robustness, long service life, and broad certification footprint reduce downtime and maintenance costs in demanding environments. Although shipped without a trip unit, the upgrade path to Power Xpert Release enables proactive protection and remote monitoring, lowering future retrofit costs. Its fixed-frame design also accelerates installation, shortening capital project timelines and improving overall project ROI.