Eaton MPSC5N3VEAXX2C Magnum PXR breaker - 100 kAIC
Part Number: MPSC5N3VEAXX2C
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial switchgear and motor feeders with reliable, three-pole overcurrent protection. Operators often contend with nuisance trips and downtime caused by undersized protection, miscoordination, or difficult field setup. UL Listed, CE Marked, and NEMA/CSA certified provide regulatory confidence, while the PXR20 LSIG trip unit supports selective coordination essential for modern bus architectures. This model integrates with Power Xpert Protection Manager for remote health monitoring and diagnostics, delivering faster fault isolation and reduced maintenance costs. The Magnum PXR family’s double-frame design and fixed vertical mounting offer installation efficiency and a scalable path for future expansion.
Product Information
Extended Description
MPSC5N3VEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (AABBCC), 100 kA, Three-pole, Fixed vertical mounting, PXR20 LSIG trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC5N3VEAXX2C
UPC
786689631666
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
SABA Listed CE Marked NEMA Compliant CCC Marked
Certifications
UL Listed ANSI CSA Certified KEMA Certified Lloyd's Register Certified ABS Certified DNV GL Certified
Frame
Double standard
Number of poles
Three-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR20 LSIG
Number of poles
Three-pole
Rated uninterrupted current (Iu)
5000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
5000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC5N3VEAXX2C
Eaton Specification Sheet - MPSC5N3VEAXX2C
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Outstanding electrical robustness is achieved with a rated uninterrupted current (Iu) of 5000 A and an interrupt rating of 100 kAIC, enabling the breaker to reliably protect feeders and motor circuits under heavy fault conditions. This translates to reduced thermal stress on conductors and minimized downtime from arc flash events, especially in large switchgear and data-driven facilities. In practice, engineers can confidently coordinate with upstream devices to achieve selective protection in complex industrial networks. Magnum PXR with LSIG trip unit delivers fast, accurate fault detection and adjustable protection settings. The LSIG mechanism enhances selective coordination, reducing unwanted trips and preserving essential loads during faults, which is critical for process industries with variable starting currents. This model’s double-frame, three-pole design with fixed vertical mounting simplifies installation in existing panels while providing a robust footprint for future expansion. Comprehensive certifications—UL Listed, CE Marked, NEMA Compliant, CSA/KEMA/ABS/DNV GL as applicable—minimize compliance risk across global sites and support long-term serviceability. Integration with Power Xpert Protection Manager enables remote monitoring, diagnostic access, and proactive maintenance planning, improving asset uptime. In practice, installers benefit from consistent mounting practices, documented manuals, and a shared product ecosystem that reduces spare-part proliferation and training time.
Get a Quick Quote for a Eaton MPSC5N3VEAXX2C
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC5N3VEAXX2C?
Enquire Now
FAQs
The MPSC5N3VEAXX2C uses a fixed vertical mounting with a double standard frame and three-pole configuration, designed to fit within Magnum PXR installations. It is compatible with the PXR20 LSIG trip unit, enabling straightforward field coordination and minimal rework when upgrading from older Magnum frames. Installation benefits include consistent footprint, documented wiring diagrams, and reduced commissioning time when paired with Power Xpert Protection Manager for configuration and diagnostics.
This breaker offers a rated uninterrupted current (Iu) of 5000 A and an interrupt rating of 100 kAIC, supporting high-demand feeders and motor circuits. These ratings enable reliable protection during faults, minimize thermal stress on conductors, and improve uptime in applications with heavy startup currents, such as pumps and large drives, while maintaining selectivity with the LSIG trip unit.
Yes. The three-pole Magnum PXR with LSIG trip unit is designed for large power distribution setups, including motor control centers and switchgear banks. Its double-frame design and robust protection capabilities support reliable motor startups and fault isolation, reducing unplanned outages in challenging environments such as metals, mining, and chemical processing facilities.
The breaker carries UL Listed and CSA/ANSI certifications and CE Marking, along with NEMA compliance and other industry validations (such as KEMA, Lloyd's Register, ABS, DNV GL where applicable). This broad certification suite helps ensure regulatory compliance across global sites and simplifies cross-border procurement and installation of low-voltage protection equipment.
Maintenance benefits come from compatibility with Power Xpert Protection Manager, with quick-start guides and monitoring tools that enable remote health checks, trip data analysis, and proactive maintenance planning. This supports lower total cost of ownership by reducing unscheduled downtime, streamlining spare parts, and enabling predictive servicing aligned with facility maintenance strategies.