Eaton MPSC5N4MEAXX2S Magnum low voltage power circuit breaker - 100 kAIC
Part Number: MPSC5N4MEAXX2S
Quick Summary
Eaton Magnum low voltage power circuit breaker provides reliable overcurrent protection for industrial distribution panels and switchgear. When uptime is non-negotiable, engineers need fast tripping, easy maintenance, and seamless integration with protection schemes. This unit carries ANSI, CSA, UL, and CE certifications along with NEMA compliance to support global deployment. With the PXR25 LSIGAM trip unit and motorized, drawout racking, it enables selective protection and rapid reconfiguration, reducing downtime. Designed for high-current, four-pole protection, it aligns with Power Xpert Protection Manager workflows, delivering robust reliability and scalable protection for complex electrical infrastructures.
Product Information
Extended Description
MPSC5N4MEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNAABBCC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR25 LSIGAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC5N4MEAXX2S
UPC
786689631314
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant SABA Listed CCC Marked CE Marked
Certifications
ANSI CSA Certified UL Listed KEMA Certified Lloyd's Register Certified DNV GL Certified ABS Certified
Frame
Double standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR25 LSIG ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
5000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
5000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC5N4MEAXX2S
Eaton Specification Sheet - MPSC5N4MEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature to business impact to application: The Magnum PXR four-pole design supports 5000 A Iu and a 100 kAIC interrupt rating, enabling reliable fault clearance in demanding distribution systems and critical manufacturing lines; this translates to improved system availability and reduced downtime in data centers and large motor drives. The drawout vertical mounting with motorized racking simplifies maintenance and replacement, cutting outage durations and enabling faster service window execution during panel upgrades or routine inspections in plant environments. The PXR25 LSIGAM protection unit provides configurable protection logic, improving selective coordination and reducing nuisance trips across complex switchgear assemblies. The double standard frame and four-pole configuration deliver compatibility with existing Magnum installations and minimize retrofit costs when upgrading mid-life infrastructure. Industry-standard certifications (ANSI, CSA, UL, CE, NEMA compliance) ensure regulatory alignment across regions, facilitating global deployments and supplier audits. These features, combined with Power Xpert Protection Manager integration, enable remote monitoring, faster fault diagnosis, and improved protective coordination, delivering measurable ROI through reduced maintenance time and fewer unplanned outages.
Get a Quick Quote for a Eaton MPSC5N4MEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC5N4MEAXX2S?
Enquire Now
FAQs
For installation, ensure space for a four-pole unit with vertical drawout access and clearance for motorized racking. Verify compatibility with Magnum PXR trip units and the panel's mounting frame. Use appropriate torque values for mounting hardware and confirm wiring clearances meet local codes. The unit’s double standard frame simplifies retrofit into existing Magnum installations and minimizes downtime during replacement.
A 100 kAIC interrupt rating indicates the breaker can interrupt high fault currents without structural damage, enabling rapid isolation of faults in large feeders, data centers, and heavy motor drives. This improves system reliability, reduces arc energy exposure, and supports safer coordination with upstream protective devices within comprehensive short-circuit protection schemes.
Yes. The Magnum PXR with LSIGAM trip unit is designed to integrate with Power Xpert Protection Manager, enabling centralized protection management, remote status monitoring, and coordinated protection settings. This compatibility supports streamlined commissioning, easier firmware updates, and improved visibility into protection performance across multiple breakers in the same substation or plant.
The MPSC5N4MEAXX2S carries ANSI and CSA certifications, UL listing, CE marking, and NEMA compliance, along with SABA and CCC markings as applicable. These certifications support global deployment, regulatory audits, and adherence to safety and performance standards in diverse markets.
Motorized racking reduces manual handling, enabling faster maintenance and quicker panel reconfigurations, which lowers downtime during inspections or upgrades. The four-pole design provides robust three-phase protection, improving reliability. Combined with selective protection from the LSIGAM trip and PXPM integration, this setup can reduce maintenance labor costs and minimize unplanned outages, delivering a favorable return on investment over the equipment lifecycle.