Eaton MPSC5N4VEAXX2A Magnum low voltage breaker - UL Listed
Part Number: MPSC5N4VEAXX2A
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial electrical systems by interrupting faults quickly and safely in demanding power-distribution panels. For engineers wrestling with nuisance trips and time-consuming fault isolation, reliable coordination is essential to keep critical processes up and running. UL Listed, ANSI certified, and CE marked—along with CSA and KEMA validation—this device meets global requirements and streamlines cross-border deployments. The four-pole Magnum frame, fixed vertical mounting, and compatibility with the PXR20 LSI trip unit enable precise protection tailored to motor control centers and switchgear. When used with Power Xpert Protection Manager, it supports scalable protection schemes, faster diagnostics, and reduced maintenance costs across the plant.
Product Information
Extended Description
MPSC5N4VEAXX2A Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNAABBCC), 100 kA, Four-pole, Fixed vertical mounting, PXR20 LSI trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC5N4VEAXX2A
UPC
786689631338
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CE Marked CCC Marked SABA Listed
Certifications
ANSI KEMA Certified CSA Certified UL Listed Lloyd's Register Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x32 22.06 1
Power Xpert Protection Manager x32 22.06 1
Eaton Specification Sheet - MPSC5N4VEAXX2A
Eaton Specification Sheet - MPSC5N4VEAXX2A
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Safer by design: arc energy reduction techniques
Four-pole design with fixed vertical mounting provides robust, space-efficient protection in crowded panels. This configuration improves bus stability and reduces installation time, making retrofits predictable for OEMs and panel builders. With a 100 kA interrupting capacity, it safely clears high fault currents, minimizing arc energy and protecting downstream equipment. The result is shorter downtime and longer life for motor starters, drives, and feeders in manufacturing and process industries. The PXR20 LSI trip unit delivers precise protection and easy coordination with downstream devices. When used with Power Xpert Protection Manager, you gain real-time monitoring, event logging, and remote diagnostics that simplify maintenance planning. UL Listed, ANSI certification, and CE marking, along with CSA and KEMA validations, provide broad compliance coverage and procurement confidence. The Magnum frame also supports Power Xpert Release trip units and compatible accessories for scalable protection schemes. In practice, engineers report improved selectivity and faster fault isolation, reducing wasted energy and enabling safer machine downtime. This combination aligns with industry standards and maintenance budgets across automotive, packaging, and process sectors.
Get a Quick Quote for a Eaton MPSC5N4VEAXX2A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC5N4VEAXX2A?
Enquire Now
FAQs
Refer to the Magnum PXR installation guide and follow Eaton's recommended practices for four-pole units. Ensure correct line/load terminal orientation, proper bus bar alignment, and secure mounting in a fixed vertical orientation. Verify PXR20 LSI trip unit settings, perform a basic functional test, and confirm correct accessories are installed before commissioning the panel.
Key specs include a four-pole configuration, 100 kA interrupting capacity, fixed vertical mounting, Magnum PXR double standard frame, and a PXR20 LSI trip unit. It is designed for high-current industrial distributions and is suitable for coordinating protection across motor control centers and switchgear in demanding environments.
Yes. It carries UL Listed, ANSI certification, and CE marking, with CSA and KEMA validations, supporting global deployment. The robust Magnum frame, NEMA compatibility, and broad certifications help ensure reliable operation in factories, process plants, and automated lines while simplifying supplier qualification and regulatory compliance.
The breaker is UL Listed, ANSI certified, and CE marked, with additional CSA Certified, KEMA Certified, Lloyd's Register Certified, ABS Certified, and DNV GL Certified endorsements. These certifications support compliance across North America, Europe, and other regions, facilitating procurement and reducing the need for repetitive testing during audits.
The combination of high interrupting capacity, precise PXR20 LSI trip, and compatibility with Power Xpert Protection Manager enables faster fault isolation, proactive maintenance, and improved uptime. In addition, certified compliance reduces qualification time, while zone-selective interlocking options and scalable accessories support longer-term protection strategy and lower lifecycle costs.