Eaton MPSC5N4WEAXX2H Magnum low-voltage power-breaker UL
Part Number: MPSC5N4WEAXX2H
Quick Summary
Eaton Magnum low-voltage power circuit breaker protects electrical distributions in industrial plants, providing reliable fault isolation and system protection. Faced with nuisance trips, coordination gaps, and costly downtime, engineers need protection that stays in specification under fault conditions. UL Listed, CE Marked, and CSA Certified ensure global compliance and streamlined procurement for multi-site operations. This model's drawout vertical mounting and PXR20 LSI ARMS trip unit aligns with Magnum PXR series for modular protection and faster maintenance.
Product Information
Extended Description
MPSC5N4WEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 5000 A (NNAABBCC), 100 kA, Four-pole, Drawout vertical mounting, PXR20 LSIAM trip unit
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC5N4WEAXX2H
UPC
786689631437
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
SABA Listed CCC Marked CE Marked NEMA Compliant
Certifications
ANSI CSA Certified KEMA Certified Lloyd's Register Certified UL Listed ABS Certified DNV GL Certified
Frame
Double standard
Number of poles
Four-pole
Type
Magnum PXR
Frame
Double standard
Series
Magnum
Trip Type
PXR20 LSI ARMS
Number of poles
Four-pole
Rated uninterrupted current (Iu)
5000 A
Interrupt rating
100 kAIC
Interrupt rating
100 kAIC
Rated uninterrupted current (Iu)
5000 A
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC5N4WEAXX2H
Eaton Specification Sheet - MPSC5N4WEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
High interrupt rating and Iu capability translate to robust fault handling, reducing damage downstream and improving overall system reliability; the business impact is measurable uptime and safer protection for critical lines in manufacturing, data centers, and process plants. The four-pole configuration and drawout vertical mounting enable full-phase protection with simple hot-swapping during maintenance, cutting downtime and enabling faster panel upgrades in existing installations. The PXR20 LSI ARMS trip unit delivers selective protection and arc-flash energy management, improving compliance and reducing nuisance trips in complex protection schemes. Compatibility with Magnum PXR frames and double-standard construction simplifies retrofits and new builds alike, lowering engineering time and training costs. The unit carries UL, CE, and CSA certifications, aligning with global procurement standards and reducing supplier risk while meeting local regulatory requirements. With dimensions of 16.3 in depth, 16.8 in height, and 44.1 in width, plus a 319 lb weight, installation foot-prints and handling are well-defined for panel design and crane-lift planning. This combination supports long-term lifecycle cost reduction and predictable maintenance budgets.
Get a Quick Quote for a Eaton MPSC5N4WEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC5N4WEAXX2H?
Enquire Now
FAQs
This unit uses a drawout vertical mounting with a four-pole frame, designed to fit standard Magnum panel configurations. Ensure sufficient clearance for maintenance, verify busbar spacing, and confirm panel cutouts accommodate the 44.1 in width. The drawout mechanism minimizes panel downtime during replacement, enabling safer, faster maintenance without full panel disassembly.
The MPSC5N4WEAXX2H provides a rated uninterrupted current (Iu) of 5000 A and an interrupt rating of 100 kAIC. It is a four-pole Magnum PXR unit with a PXR20 LSI ARMS trip system, suitable for high-demand, 3-phase distribution with precise protection and fast fault clearance.
Yes. The product is UL Listed, CE Marked, and CSA Certified, aligning with North American and European regulatory requirements. This simplifies multi-site procurement and reduces regulatory risk when integrating into compliant power distribution systems.
The drawout design and PXR20 ARMS provide faster replacement and precise protection coordination, reducing downtime during maintenance and enhancing system reliability. Over the lifecycle, this translates to lower maintenance costs, improved uptime, and a faster return on investment through fewer unplanned outages.
This breaker is designed for seamless integration with Magnum PXR protection modules, including drawout mounting and PXR20 ARMS. It supports scalable protection strategies, simplified commissioning with Protection Manager tools, and easier coordination with upstream and downstream devices for reliable selective protection.