Eaton MPSC603WEAXX2S Magnum low voltage breaker - UL Listed
Part Number: MPSC603WEAXX2S
Quick Summary
Eaton Magnum low voltage power circuit breaker protects critical electrical systems in industrial power distribution. In demanding facilities, proper protection and coordination prevent nuisance trips and costly downtime. The unit carries UL Listed, CE Marked, and CSA Certified classifications to meet global safety and compliance requirements. Designed for Power Xpert Protection Manager compatibility and drawout vertical mounting, it delivers reliable protection with straightforward maintenance, helping facilities boost uptime and reduce operating costs.
Product Information
Extended Description
MPSC603WEAXX2S Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (ABCABC), 100 kA, Three-pole, Drawout vertical mounting, PXR25 LSIGAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC603WEAXX2S
UPC
786689632403
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked NEMA Compliant SABA Listed CCC Marked
Certifications
UL Listed CSA Certified KEMA Certified Lloyd's Register Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC603WEAXX2S
Eaton Specification Sheet - MPSC603WEAXX2S
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: The PXR25 LSIGAM electronic trip unit provides precise short-circuit protection and adjustable trip settings. Business Impact: This enables tighter selective coordination, reduces nuisance trips, and minimizes arc energy exposure, enhancing operator safety. Application: It's well-suited for motor feeders and critical loads in automation lines, packaging equipment, and process systems where uptime is essential. Feature: Drawout vertical mounting simplifies installation and maintenance inside large switchgear enclosures. Business Impact: technicians can swap breakers quickly, reduce panel downtime, and lower labor costs during upgrades or replacements. Application: ideal for retrofit projects and new installations in factories with space constraints or modular architectures. Feature: Three-pole design with a 6000 A frame and 100 kA interrupt rating delivers robust fault handling for high-current systems. Business Impact: improved protection for feeders and main circuits, reduced risk of cascading outages, and longer equipment life. Application: suitable for main feeders and critical branch circuits in manufacturing plants and water treatment facilities. Feature: The Magnum unit measures 16.3 in depth, 16.8 in height, and 31.1 in width with a 237 lb weight, designed for compatibility with standard Magnum frames. Business Impact: ensures reliable fit in large enclosures while maintaining serviceability and replacement parts availability. Application: installation in drawout vertical mounting configurations within existing power distribution cabinets. Feature: Compliances and certifications include UL Listed, CSA Certified, CE Marked, NEMA Compliant, SABA Listed, CCC Marked, and more. Business Impact: regulatory alignment accelerates procurement, reduces supplier risk, and supports global deployment. Application: widely deployed across North American and international facilities that demand proven safety and performance.
Get a Quick Quote for a Eaton MPSC603WEAXX2S
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC603WEAXX2S?
Enquire Now
FAQs
For retrofit or new installs, verify enclosure space for the 31.1 in width Magnum frame and plan for drawout vertical mounting. Ensure proper alignment with bus bars, follow the PXR25 LSIGAM trip unit settings, and confirm panel clearance and wiring terminations meet NEC and UL requirements. Use compatible fittings and torque specs per Eaton manuals to minimize commissioning time.
Key specs include a 3-pole configuration, 6000 A frame, 100 kA interrupt rating, 16.3 in depth, 16.8 in height, 31.1 in width, and a weight of 237 lb. It uses the PXR25 LSIGAM electronic trip unit for precise coordination and protection, and supports drawout vertical mounting for easy maintenance and replacement.
Yes. With UL Listed, CSA Certified, CE Marked, and NEMA compliance, the MPSC603WEAXX2S is appropriate for regulated environments requiring robust protection and global conformity. Its drawout design and Power Xpert protection compatibility support factory automation, packaging lines, and process streams common in pharma and food & beverage operations.
The unit carries UL Listed, CSA Certified, CE Marked, KEMA/Certifications, Lloyd's Register, ANSI, DNV GL, ABS, plus SABA and CCC markings. This mix facilitates cross-border procurement, ensures safety compliance, and supports audits across North America, Europe, and other regional markets.
The MPSC603WEAXX2S offers reliable protection with a long service life, reducing unexpected outages and maintenance costs. By enabling selective coordination and easy maintenance through drawout mounting, facilities can shorten downtime during servicing, optimize energy usage, and improve overall plant productivity with Power Xpert Protection Manager integration.