Eaton Magnum LV Circuit Breaker MPSC604EEAXX2F - UL Listed
Part Number: MPSC604EEAXX2F
Quick Summary
Eaton Magnum LV Circuit Breaker protects electrical distribution panels in industrial facilities. Designers and maintenance teams confront selective coordination and downtime challenges in demanding environments, where a single fault can escalate to costly outages. This unit carries UL Listed, CE Marked, and CSA Certified approvals, enabling broad regulatory compliance across regions. The Magnum PXR trip unit provides precise protection and flexible coordination, while the four-pole, drawout vertical design simplifies installation and maintenance in compact switchgear. With a 100 kA interrupting rating and strong NEMA/IEC alignment, it supports scalable protection for growing facilities, reducing spare parts inventory and simplifying retrofit projects.
Product Information
Extended Description
MPSC604EEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNABCABC), 100 kA, Four-pole, Drawout vertical with extensions mounting, PXR20 LSIGAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC604EEAXX2F
UPC
786689631918
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
SABA Listed NEMA Compliant CE Marked CCC Marked
Certifications
Lloyd's Register Certified UL Listed CSA Certified KEMA Certified ANSI ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC604EEAXX2F
Eaton Specification Sheet - MPSC604EEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The PXR20 LSIGAM trip unit delivers advanced overcurrent protection with adjustable long and short-time delay settings, enabling precise coordination and reducing nuisance trips. In practice, this improves uptime and enhances feeder protection across complex switchgear configurations. When paired with Eaton's Power Xpert Protection Manager, technicians can remotely configure, monitor, and document protection settings, accelerating commissioning and ongoing compliance checks. The four-pole, drawout vertical design with extensions makes installation and service easier in tight spaces, lowering maintenance labor and enabling fast swap-outs during preventive maintenance windows. The 100 kA interrupting rating and 6000 A maximum current rating provide headroom for high fault currents common in large industrial plants, improving system resilience during faults. Certifications and global approvals enable cross-border project execution with fewer redlines, while renewal parts and extensive manuals support a lower lifecycle cost and longer service life. This combination offers tangible ROI through reduced downtime, simplified retrofits, and streamlined compliance reporting for power distribution networks.
Get a Quick Quote for a Eaton MPSC604EEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC604EEAXX2F?
Enquire Now
FAQs
When retrofitting, verify the panel supports a four-pole drawout design and that the mounting arrangement matches the vertical extensions. Confirm the busbar spacing and connector compatibility with the MPSC604EEAXX2F catalog specifications. Plan for coordination settings using the PXR20 LSIGAM trip unit and consider back-up protection with the Power Xpert Protection Manager for centralized configuration and documentation.
Key specs include a four-pole configuration, 100 kA interrupting rating, and a 6000 A maximum current rating, with the PXR20 LSIGAM trip unit providing adjustable protection curves. These enable tight selective coordination between feeders and main breakers, reducing the likelihood of cascading trips and enabling faster fault isolation while maintaining system reliability in high-current industrial applications.
Yes. With a 100 kA interrupting rating and four-pole design, the MPSC604EEAXX2F is well-suited for high-current industrial environments and data-center feed panels where reliable fault protection and coordination are essential. Its Magnum frame supports scalable distribution, while UL Listed and CSA/CE certifications simplify deployment across multi-region facilities.
Key certifications include UL Listed, CSA Certified, CE Marked, and additional approvals such as KEMA, Lloyd's Register, ANSI, ABS, and DNV GL. In North America, UL and CSA cover electrical safety and performance, while CE Marking simplifies EU compliance. These certifications support cross-border projects and help meet regulatory and safety requirements.
Lifecycle benefits come from availability of renewal parts, comprehensive manuals, and compatibility with Power Xpert Protection Manager for ongoing monitoring and updates. The design facilitates easier field maintenance with a drawout mechanism, reducing downtime during servicing. Overall, this supports lower total cost of ownership through longer service intervals, streamlined spares strategy, and easier retrofit planning.