Eaton Magnum MPSC604MEAXX2A Low-Voltage Circuit Breaker UL
Part Number: MPSC604MEAXX2A
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial panels in demanding manufacturing environments. Many users struggle with downtime and miscoordination in complex electrical rooms, especially during maintenance or equipment changes. Key certifications such as UL Listed, CE Marked, and NEMA Compliant ensure regulatory readiness across global sites. This model also supports Power Xpert Protection Manager and the PXR20 trip unit for scalable protection, while its drawout vertical mounting with motorized racking simplifies service and reduces commissioning time. By combining robust interrupt capability with easy integration, it delivers reliable protection and faster project ROI across a range of industrial applications.
Product Information
Extended Description
MPSC604MEAXX2A Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNABCABC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR20 LSI trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC604MEAXX2A
UPC
786689632038
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked NEMA Compliant CCC Marked SABA Listed
Certifications
UL Listed Lloyd's Register Certified CSA Certified KEMA Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC604MEAXX2A
Eaton Specification Sheet - MPSC604MEAXX2A
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
The Magnum MPSC604MEAXX2A employs a four-pole configuration with a 100 kA short-circuit current rating, delivering robust fault isolation. This high interrupt capability protects downstream equipment and minimizes arc energy during faults. Together with a 6000 A frame rating, it supports reliable protection for large feeders and motor circuits in demanding facilities. Equipped with the PXR20 LSI trip unit, the breaker delivers precise protection logic and configurable trip curves. This enables improved selective coordination with upstream protective devices and reduces nuisance trips in multi-cabinet installations. The result is higher equipment availability and safer, more predictable shutdowns during fault conditions. Drawout vertical mounting with motorized racking simplifies installation, testing, and maintenance in switchgear and panel boards. Engineers benefit from faster replacements and easier field servicing, reducing downtime during cabinet swaps. This design also supports rapid retrofit projects where existing gear must be updated without extensive rework. Power Xpert Protection Manager compatibility enables remote monitoring, event logging, and centralized protection management across the plant. This digital integration supports data-driven maintenance, faster fault diagnosis, and adherence to selective coordination standards in modern factories. Global certifications such as UL Listed, CE Marked, and NEMA compliance provide regulatory confidence for multinational deployments. Extensive approvals, including CSA, KEMA, Lloyd's Register, and ABS, simplify procurement and reduce compliance risk across sites and projects. Supply chain considerations: renewal parts and compatible accessories are readily available, helping extend service life with minimal downtime. In practice, customers report lower total cost of ownership when using Magnum PX R units for long-term protection. Installation practices: The unit's drawout design aligns with standard switchgear interface dimensions for faster cabling and racking.
Get a Quick Quote for a Eaton MPSC604MEAXX2A
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC604MEAXX2A?
Enquire Now
FAQs
The MPSC604MEAXX2A is designed for vertical drawout mounting with motorized racking, facilitating quick cabinet swaps and reduced downtime. Ensure compatibility with standard switchgear interfaces, proper clearance for racking, and adherence to safe-lockout procedures during maintenance to maximize uptime.
This model is UL Listed and CE marked, with additional NEMA compliance and other approvals such as CSA, KEMA, and Lloyd's Register. These certifications validate regulatory compliance across global sites, simplify procurement, and support risk reduction in multinational projects.
It features a four-pole design, a 6000 A frame rating, and a 100 kA short-circuit current rating (SCCR). These ratings enable reliable protection for large feeders and motor circuits in demanding industrial environments while maintaining coordination with upstream protection.
Yes. The MPSC604MEAXX2A supports Power Xpert Protection Manager and PXR20 trip units, enabling remote monitoring, event logging, and centralized protection management for smarter maintenance and improved coordination across the plant.
Ideal for large distribution panels, motor control centers, and machine-building environments, especially where high fault protection, reliable coordination, and easy serviceability are required. It’s commonly deployed in manufacturing, processing, and heavy-duty packaging facilities seeking robust short-circuit protection and downtime reduction.