Eaton Magnum low voltage power circuit breaker MPSC604MEAXX2F - UL Listed
Part Number: MPSC604MEAXX2F
Quick Summary
Eaton Magnum low voltage power circuit breaker protects electrical systems in industrial equipment and motor control centers. Choosing protection that balances reliability, selectivity, and maintenance costs is a frequent challenge for design teams. With UL Listed, CE Marked, and third-party certifications such as KEMA and Lloyd's Register, the Magnum PXRs meet stringent global standards. This combination supports safe operations, faster maintenance, and scalable protection for motor drives and process lines. In practice, engineers gain peace of mind knowing a rugged, code-compliant solution is ready for critical applications. The drawout design and motorized racking simplify replacement during outages, while the 100 kA rating and 6000 A frame provide robust protection under demanding loads.
Product Information
Extended Description
MPSC604MEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNABCABC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR20 LSIGAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC604MEAXX2F
UPC
786689632052
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
NEMA Compliant CCC Marked SABA Listed CE Marked
Certifications
KEMA Certified Lloyd's Register Certified ANSI UL Listed CSA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC604MEAXX2F
Eaton Specification Sheet - MPSC604MEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Four-pole, heavy-duty protection with a compact footprint. Business Impact: Enables robust phase coordination and protection for multi-phase motors while maximizing panel space in control rooms and switchgear. Application: Suitable for motor control centers and process lines where space is at a premium. Feature: Drawout vertical mounting with motorized racking. Business Impact: Speeds maintenance and replacement, reducing downtime and labor costs. Application: Ideal for one-person preventive maintenance and rapid swap-out during outages. Feature: PXR20 LSIGAM trip unit. Business Impact: Delivers precise protection settings and improved selectivity, lowering arc-flash risk and improving downtime predictability. Application: Critical in high-demand applications such as conveyor systems and high-inertia loads. Feature: 100 kA interrupting capacity and 6000 A frame rating. Business Impact: Ensures safe interruption of large fault currents, improving equipment longevity and safety. Application: Essential for critical power distribution in manufacturing and process facilities. Feature: Fan-cooled operation and rugged construction. Business Impact: Maintains performance in harsh environments, reducing thermal-related nuisance trips. Application: Industrial environments with elevated ambient temperatures or dense cabinet assemblies. Feature: Broad certifications (UL Listed, CE Marked, KEMA, Lloyd's Register, ANSI, CSA, ABS, DNV GL). Business Impact: Facilitates global compliance and streamlined procurement across regions. Application: Global operations requiring multi-standard certification. The combination of compatibility with Magnum PXR trip units, motorized racking, and the four-pole design supports scalable protection strategies while delivering measurable efficiency, safety, and cost savings across the plant lifecycle.
Get a Quick Quote for a Eaton MPSC604MEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC604MEAXX2F?
Enquire Now
FAQs
The MPSC604MEAXX2F is designed for drawout vertical mounting with motorized racking and is compatible with Magnum PXR protection units. Ensure your panel supports four-pole configurations and has space for a 16.3 in depth, 16.8 in height, and 44.1 in width assembly. Verify mounting rails and racking mechanisms match the unit's requirements to enable seamless hot-swappable operation.
Key ratings include a 100 kA interrupting capacity and a 6000 A frame rating, four poles, and a fan-cooled design. The unit uses the PXR20 LSIGAM trip unit, enabling precise protection settings and enhanced selectivity for motor control centers and process lines.
Yes. The four-pole design, drawout mounting with motorized racking, and rugged construction make it ideal for motor control centers in heavy industry. Its high interrupting capacity, combined with LSIGAM trip protection and fan cooling, supports reliable operation in demanding conditions.
The unit is UL Listed and CE Marked, with additional third-party certifications including KEMA and Lloyd's Register. It also carries ANSI, CSA, ABS, and DNV GL certifications, supporting regulatory compliance across global installations.
Power Xpert Protection Manager software is available for protection management, with quick-start guides and user manuals provided by Eaton. Regular firmware and software updates align with evolving protection strategies, helping optimize coordination, diagnostics, and remote monitoring while reducing on-site maintenance burden.