Eaton MPSC604WEAXX2C Magnum LV circuit breaker - UL Listed

Part Number: MPSC604WEAXX2C
Manufacturer
Eaton
Part number
MPSC604WEAXX2C

Quick Summary

Magnum low voltage power circuit breaker protects industrial electrical distributions in packaged systems and turnkey controls. Engineers often contend with coordinating protective devices and minimizing downtime during maintenance or upgrades. It carries UL Listed and ANSI listings with CE Marked compatibility to support global compliance. Designed for power management and distribution reliability, it supports Power Xpert Release trip units and seamless integration with Eaton protection software for faster fault isolation and reduced downtime. For procurement teams, the combination of robust protection and documented certifications reduces supplier risk and simplifies audits.

Product Information

Extended Description

MPSC604WEAXX2C Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNABCABC), 100 kA, Four-pole, Drawout vertical mounting, PXR20 LSIG trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC604WEAXX2C
UPC
786689632786
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CCC Marked CE Marked NEMA Compliant SABA Listed
Certifications
Lloyd's Register Certified CSA Certified KEMA Certified ANSI UL Listed ABS Certified DNV GL Certified
Feature → Business Impact → Application: Four-pole, drawout vertical mounting with PXR20 LSIG trip unit provides precise, selective protection while simplifying replacement during maintenance. This combination reduces arc energy exposure and speeds up replacement work, translating to less downtime and safer panel work. In practice, it suits large motor control centers and distributed power panels where fast, reliable protection is essential. Feature → Business Impact → Application: The Magnum design achieves 6000 A breaking capacity (NNABCABC) and 100 kA short-circuit rating. This capability shields feeders from high-energy faults and minimizes collateral damage in major fault events. It is particularly valuable in continuous-process environments like steel, cement, and chemical plants where downtime is costly. Feature → Business Impact → Application: Drawout vertical mounting improves serviceability by permitting hot-swap replacements without panel disassembly. This reduces commissioning time and improves safety during breaker changes. It is especially beneficial in retrofit projects or expansions where space is constrained and utilities require rapid protection upgrades. Feature → Business Impact → Application: The PXR20 LSIG protection unit enables advanced coordination with other breakers and protection devices, supporting selective tripping. This translates to shorter outage windows and better fault localization in complex power networks. It pairs with Power Xpert Protection Manager for centralized monitoring and alarm management across facilities. Feature → Business Impact → Application: Full compliance footprint includes UL Listed, ANSI, CE, and other certifications, lowering procurement risk and accelerating audits. Vendors and owners gain documented traceability and easier cross-border installation. For global projects, this certification set simplifies supplier qualification and reduces compliance costs. For teams managing multi-site deployments, standardized protection criteria and documented data sheets help ensure consistent performance across facilities.

Get a Quick Quote for a Eaton MPSC604WEAXX2C

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton MPSC604WEAXX2C? Enquire Now

FAQs

Yes. The unit is a four-pole, drawout vertical-mount Magnum LV circuit breaker designed for standard low-voltage panels. It fits typical bus configurations and can be hot-swapped with minimal panel disruption. Ensure proper torque and alignment, and verify compatibility with Power Xpert Release trip units when coordinating protection across panels.
The breaker offers a 6000 A breaking capacity (NNABCABC) and a 100 kA short-circuit rating, enabling robust fault interruption for large feeders. The PXR20 LSIG trip unit provides adaptive protection curves and coordination with upstream devices, supporting reliable operation in demanding industrial networks.
Absolutely. The four-pole design, high breaking capacity, and drawout mounting are ideal for motor control centers and heavy industry environments such as steel, cement, and chemical plants where uptime and protective coordination are critical. The unit also supports scalable protection strategies with Eaton’s protection software.
The MPSC604WEAXX2C carries UL Listed and ANSI listings with CE Marked compatibility, along with broader certifications such as NEMA compliance. This combination supports global deployments, audits, and supplier qualification across North America and Europe.
Investing in this Magnum breaker yields faster maintenance through drawout design, safer hot-swaps, and reduced downtime during protection upgrades. Its high fault-current ratings and integration with Power Xpert Protection Manager enable proactive monitoring and optimized protection coordination, leading to lower service costs and higher system availability.