Eaton MPSC604WEAXX2F Magnum low voltage power circuit breaker - UL Listed
Part Number: MPSC604WEAXX2F
Quick Summary
Eaton Magnum low voltage power circuit breaker MPSC604WEAXX2F provides reliable fault protection for industrial power distribution panels. Design challenges in crowded switchgear and the need for fast, selective tripping can drive maintenance downtime and risk; this unit's four-pole, drawout vertical mounting streamlines installation in tight cabinets. This model carries UL Listed, CE Marked, and CSA Certified credentials, plus Lloyd's Register and ANSI certifications, supporting global compliance. Integrated with the Power Xpert Protection Manager and the PXR20 LSIGAM trip unit, it enables precise protection coordination while simplifying configuration and service. Industrial facilities benefit from reduced downtime, improved safety, and easier future upgrades with this versatile Magnum breaker.
Product Information
Extended Description
MPSC604WEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NNABCABC), 100 kA, Four-pole, Drawout vertical mounting, PXR20 LSIGAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC604WEAXX2F
UPC
786689632793
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked NEMA Compliant SABA Listed CCC Marked
Certifications
Lloyd's Register Certified CSA Certified UL Listed KEMA Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC604WEAXX2F
Eaton Specification Sheet - MPSC604WEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature → Business Impact → Application: The PXR20 LSIGAM trip unit provides precise, selectable protection, reducing nuisance trips and extending equipment life; this translates to lower maintenance costs and higher line uptime in continuous manufacturing environments such as packaging lines and process controls. The 6000 A frame with a 100 kA withstand rating supports high fault-current scenarios, enabling safer service in heavy industry, data centers, and large motor applications. Four-pole design with drawout vertical mounting simplifies wiring, inspection, and replacement in crowded switchgear cabinets, speeding commissioning and maintenance in control centers and machine rooms. Comprehensive certifications (UL Listed, CE Marked, CSA Certified, plus Lloyd's Register and ANSI) mitigate regulatory risk, supporting multi-region deployments and customer audits. Compatibility with Power Xpert Protection Manager allows centralized protection logic, event logging, and remote configuration, reducing on-site visits and enabling predictive maintenance programs. The Magnum family’s renewals and spare parts ecosystem reduces lifecycle costs and extends asset longevity, a crucial factor in capital-intensive plants. Zone selective interlocking and coordinated protection concepts can be implemented with available application papers and product guides, accelerating engineering workflows and reducing design risk.
Get a Quick Quote for a Eaton MPSC604WEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC604WEAXX2F?
Enquire Now
FAQs
To install the MPSC604WEAXX2F, prepare a drawout vertical mounting setup, verify clearance for four poles, connect control and output wiring per applicable wiring diagrams, and secure the unit in the panel frame. Use compatible bus bars and torque specs from the Magnum PXR installation guide to ensure proper seating and fault protection coordination.
This breaker is designed for industrial power distribution and machine control panels where high fault current protection, precise tripping, and reliable uptime are essential. It supports heavy industry, packaging lines, and process automation with a four-pole configuration and a PXR20 LSIGAM trip unit for selective coordination.
Yes. The unit is UL Listed, CE Marked, and CSA Certified, with additional approval from Lloyd's Register and ANSI. These certifications support global installations and regulatory audits across multiple regions.
The MPSC604WEAXX2F uses the PXR20 LSIGAM trip unit, and it is compatible with Eaton Power Xpert Protection Manager for centralized protection monitoring, event logging, and remote configuration. This integration simplifies protection schemes and helps optimize maintenance schedules.
Key specs include four poles, drawout vertical mounting, 6000 A frame with 100 kA short-circuit rating, dimensions of 16.3 in depth, 16.8 in height, and 44.1 in width, with a weight of 319 lb. The catalog number is MPSC604WEAXX2F and the UPC is 786689632793, supporting large-panel deployment.