Eaton Magnum LV Breaker MPSC6A4GEAXX2F - UL Listed
Part Number: MPSC6A4GEAXX2F
Quick Summary
Eaton Magnum LV Breaker is a low-voltage power circuit breaker designed for protection and control in industrial distribution panels. It supports demanding applications from motor feeders to main power distribution with a 6000 A NABCNABC rating and 100 kA interrupt capability. This design helps maintain uptime by delivering reliable tripping performance and simple maintenance through drawout mounting and motorized racking. Facility teams often struggle with compact space, timely replacement, and accurate coordination across feeders; the Magnum PXR trip unit supports precise protection settings to minimize nuisance trips. With UL Listed, CE Marked, and CSA Certified coverage, this device meets global standards. Built-in compatibility with Power Xpert Protection Manager enhances monitoring, reporting, and asset health for industry-grade reliability and efficiency.
Product Information
Extended Description
MPSC6A4GEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NABCNABC), 100 kA, Four-pole, Drawout vertical with extensions and motorized racking mounting, PXR20 LSIGAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6A4GEAXX2F
UPC
786689633004
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CCC Marked NEMA Compliant SABA Listed CE Marked
Certifications
KEMA Certified ANSI Lloyd's Register Certified UL Listed CSA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6A4GEAXX2F
Eaton Specification Sheet - MPSC6A4GEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Drawout vertical with extensions and motorized racking mounting enables rapid insertion and removal without sacrificing alignment or safety. This reduces maintenance downtime and improves service window planning, while preserving correct cable connections through standardized extensions. The configuration is well-suited for motor control centers, switchgear, and panelboards where space is tight and reliability is critical. PXR20 LSIGAM trip unit delivers advanced protection with adjustable long-time, short-time, and instantaneous curves and reliable arc-flash mitigation features. It reduces nuisance tripping, enables precise coordination, and simplifies code compliance for motor-driven loads. The high interrupting capacity supports fault currents common in large motors and feeders, reducing the risk of cascading failures. The four-pole design with drawout mounting ensures safe disconnection and accessibility during maintenance, valuable in multi-branch feeders requiring selective coordination. Despite its substantial footprint, the Magnum balances protection with practical fit given its 16.3 in depth, 16.8 in height, and 44.1 in width, and 319 lb weight. Certifications span UL Listed, CE Marked, CSA Certified, plus additional recognitions, supporting global procurement and audits. Seamless compatibility with Power Xpert Protection Manager enables remote monitoring, event logging, and health diagnostics, helping engineers optimize protection settings, justify ROI, and extend circuit life.
Get a Quick Quote for a Eaton MPSC6A4GEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6A4GEAXX2F?
Enquire Now
FAQs
The MPSC6A4GEAXX2F is a four-pole, drawout vertical breaker with extensions and motorized racking mounting. This configuration allows rapid swaps with precise alignment, minimized torching of cables, and safer maintenance. It is well-suited for motor control centers, switchgear, and panelboards where service windows are limited. For retrofits, ensure panel cutouts and extension kits align with the existing bus and wiring harness to maintain protection coordination.
The PXR20 LSIGAM trip unit provides adjustable protection curves (long-time, short-time, instantaneous) and precise motor protection settings. This reduces nuisance trips while maintaining coordination with upstream protection, supporting safer motor starting and longer motor life. It also simplifies compliance with relevant electrical codes by ensuring consistent trip performance across feeders.
Yes. The breaker supports coordinated protection schemes through its four-pole design, LSIGAM trip unit, and factory-proven trip curves. For optimal selective coordination, align trip settings with downstream devices and use zone selective interlocking where available. Detailed coordination papers from Eaton can guide exact settings for your bus architecture and feeder arrangement.
The device carries UL Listed and CE Marked certifications, and is also recognized as CSA Certified, with additional approvals such as ANSI, ABS, DNV GL, and Lloyd's Register where applicable. This broad certification footprint supports global procurement, reduces audit risk, and simplifies regulatory compliance across regions and customer requirements.
Integrating with Power Xpert Protection Manager enables centralized monitoring, event logging, and health diagnostics, enabling predictive maintenance and reduced unplanned downtime. The enhanced visibility supports optimized protection settings, faster fault diagnosis, and extended asset life. While upfront integration requires configuration, the long-term gains include lower maintenance costs, improved uptime, and easier compliance reporting.