Eaton MPSC6A4MEAXX2F Magnum LV Breaker - UL Listed
Part Number: MPSC6A4MEAXX2F
Quick Summary
Eaton Magnum low voltage power circuit breaker protects industrial power systems by interrupting fault currents in motor and panel applications. In fast-moving plants, nuisance tripping and difficult maintenance slow production and inflate service costs. CE Marked, UL Listed, and CSA Certified, this breaker aligns with global safety standards while supporting modern protection schemes. Leverage Power Xpert Protection Manager integration for streamlined configuration and monitoring. This combination drives reliability and cost efficiency across motor control centers and switchgear. With a four-pole design, 6000 A frame rating, and 100 kA interrupt capacity, it delivers dependable protection under demanding loads. Its drawout, motorized-racking mounting simplifies maintenance during shutdown windows, reducing downtime. Coupled with the PXR20 LSIGAM trip unit, operators gain precise protection settings and fast fault isolation.
Product Information
Extended Description
MPSC6A4MEAXX2F Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (NABCNABC), 100 kA, Four-pole, Drawout vertical with motorized racking mounting, PXR20 LSIGAM trip unit, Fan-cooled
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6A4MEAXX2F
UPC
786689632472
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
44.1 in
Product Weight
319 lb
Compliances
CE Marked SABA Listed NEMA Compliant CCC Marked
Certifications
KEMA Certified CSA Certified UL Listed Lloyd's Register Certified ANSI DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6A4MEAXX2F
Eaton Specification Sheet - MPSC6A4MEAXX2F
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Drawout vertical design with motorized racking mounting enables quick, safe replacement of a failed breaker without disconnecting all feeders. The motorized racking reduces maintenance windows and minimizes exposure to live equipment, translating to shorter downtime and safer, more predictable outages. This configuration is particularly advantageous in motor control centers and switchgear where routine maintenance and selective isolation are common requirements. The four-pole PXR20 LSIGAM electronic trip unit provides adaptable protection curves, enabling precise coordination with downstream devices and accelerating fault isolation to reduce arc-flash exposure. High interrupt ratings of 100 kA and a 6000 A frame rating safeguard demanding loads and large motors, supporting reliable operation in heavy industries. A fan-cooled design maintains performance in hot environments, minimizing derating and extending service intervals. Compliance with CE, UL, CSA, and other major certifications ensures regulatory acceptance across global plant environments. The Magnum system integrates with Power Xpert Protection Manager for centralized protection settings, event logs, and remote monitoring, simplifying engineering and maintenance workflows for modern factories.
Get a Quick Quote for a Eaton MPSC6A4MEAXX2F
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6A4MEAXX2F?
Enquire Now
FAQs
Yes. The MPSC6A4MEAXX2F features a drawout vertical design with motorized racking mounting, engineered for retrofit and new builds in motor control centers and switchgear. Verify cabinet footprint matches the 16.3 in L, 16.8 in H, and 44.1 in W dimensions and confirm the four-pole configuration aligns with your system’s protection scheme.
Key specs include a 6000 A frame rating and 100 kA interrupt capacity, four-pole construction, and the PXR20 LSIGAM electronic trip unit. The unit is fan-cooled for reliability in hot environments and supports motor protection coordination with selective tripping strategies, ideal for high-demand MCCs and distribution panels.
Industries with heavy motor loads and critical uptime needs benefit, including manufacturing, mining, water/wastewater, and process industries. The four-pole, high interrupt-capacity design supports motor control centers, switchgear, and large distribution panels requiring robust protection, quick fault isolation, and straightforward maintenance access.
The MPSC6A4MEAXX2F is CE Marked, UL Listed, and CSA Certified, with additional certifications from KEMA, Lloyd's Register, ANSI, DNV GL, and ABS. These certifications ensure regulatory compliance, global acceptance, and alignment with safety and performance standards across diverse markets and industries.
Resources include product datasheets, application notes, and manuals such as the Magnum PxR product aids and protection manager guides. Integration with Power Xpert Protection Manager enables centralized configuration, monitoring, and faster maintenance planning, contributing to lower maintenance costs and improved system availability over the lifecycle.