Eaton Magnum low voltage MPSC6N3GEAXX2H - UL Listed, CE
Part Number: MPSC6N3GEAXX2H
Quick Summary
Eaton Magnum low voltage power circuit breaker MPSC6N3GEAXX2H protects electrical distribution panels in industrial facilities. Downtime and maintenance complexity during upgrades can erode productivity; this unit’s drawout design, motorized racking, and PXR20 trip unit streamline service. UL Listed, CE Marked, and NEMA compliant, with additional approvals from Lloyd’s Register and others, help ensure regulatory readiness across global operations. This combination supports efficient power distribution, fast device replacement, and scalable protection strategies for manufacturing, processing, and data-center environments. Its compatibility with Magnum PXR trip units and Power Xpert Protection Manager enables seamless coordination and visibility across plant-level protection schemes.
Product Information
Extended Description
MPSC6N3GEAXX2H Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 100 kA, Three-pole, Drawout vertical with extensions and motorized racking mounting, PXR20 LSIAM trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6N3GEAXX2H
UPC
786689630171
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked SABA Listed CCC Marked NEMA Compliant
Certifications
ANSI UL Listed Lloyd's Register Certified KEMA Certified CSA Certified ABS Certified DNV GL Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Magnum PXR low voltage power circuit breakers user manual
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6N3GEAXX2H
Eaton Specification Sheet - MPSC6N3GEAXX2H
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Cyber security white paper
Cyber security white paper
Cyber security white paper
Feature: Drawout vertical mounting with extensions and motorized racking mounting enables rapid, safe maintenance and quick replacement, reducing downtime and labor costs. Business Impact: Improves maintenance efficiency and extends service intervals, lowering total ownership cost in high-demand panels. Application: Ideal for factory floors and process plants where frequent device access is needed without compromising safety. Feature: PXR20 LSIAM trip unit provides adaptive protection and precise coordination, improving selectivity and fault isolation. Business Impact: Minimizes collateral damage during faults, enhancing system reliability and reducing unplanned outages. Application: Suitable for motor-driven loads and critical processes requiring accurate protection settings. Feature: High interrupting capacity of 6000 A and 100 kA short-circuit rating delivers robust fault withstand for large distribution schemes. Business Impact: Supports safe operation in heavy-duty environments and simplifies code-compliant design. Application: Heavy industry, assembly lines, and multi-panel switchgear. Feature: Three-pole design and drawout format support 3-phase systems with ease of integration. Business Impact: Streamlines installation in standard 3P3W or 3P configurations, improving time to load. Application: Commercial and industrial power distribution. Feature: Broad certification portfolio including UL Listed, CE Marked, NEMA Compliant, and additional third-party approvals. Business Impact: Reduces regulatory risk and accelerates project approvals. Application: Global distribution and multinational facilities. Feature: Compatibility with Magnum PXR and renewal parts ensures long-term support and upgradeability. Business Impact: Extends asset life and protects capital investments. Application: Retrofit and lifecycle maintenance across existing installations.
Get a Quick Quote for a Eaton MPSC6N3GEAXX2H
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6N3GEAXX2H?
Enquire Now
FAQs
Plan for vertical drawout mounting with extensions and motorized racking, ensuring adequate clearance for full rack movement and safe operation. Verify panel compatibility, align bus stabs, and follow torque specs for mounting hardware. Maintain space for tool access and a clear path for racking operations to minimize maintenance time.
Yes. The unit is a three-pole device with Power Xpert Release (PXR20) LSIAM trip unit, enabling precise protection and selective coordination for motor-driven loads. It supports high fault withstand (100 kA) and integrates with standard 3P3W systems, making it well-suited for manufacturing lines and heavy-duty applications.
The MPSC6N3GEAXX2H is UL Listed and CE marked, with NEMA compliance and additional approvals from organizations like Lloyd’s Register, CCC, and CSA/DNV GL as applicable. This broad certification portfolio helps streamline approvals across global sites and reduces compliance risk in multinational projects.
Renewal parts and accessories for Magnum PXR trip units are documented in Eaton’s renewal materials, including service papers and user guides. Upgrades to the PXR20 unit can be coordinated through authorized Eaton channels, ensuring continued protection performance and compatibility with existing breakers and application software such as Power Xpert Protection Manager.
Expect reduced unplanned downtime due to precise protection and fast, safe maintenance with motorized racking. The device’s high interrupting capacity and robust certifications support long service life, easier compliance, and lower lifecycle costs, delivering improved uptime, safer maintenance, and predictable total cost of ownership for high-demand production environments.