Eaton Magnum MPSC6N3GEAXXSW Low Voltage Circuit Breaker - UL Listed
Part Number: MPSC6N3GEAXXSW
Quick Summary
Eaton Magnum MPSC6N3GEAXXSW is a low-voltage power circuit breaker for three-pole protection in industrial switchgear. When maintenance windows are tight, reliability and safe motorized racking mounting become critical for uptime. It carries CE Marked, UL Listed, and CSA Certified approvals to support global compliance. With compatibility for Power Xpert Release trip units and a space-conscious drawout design, it supports streamlined protection schemes, simplified procurement, and improved uptime across global plants.
Product Information
Extended Description
MPSC6N3GEAXXSW Eaton: Eaton Magnum low voltage power circuit breaker, Magnum PXR, Double standard frame, 6000 A (AABBCC), 100 kA, Three-pole, Drawout vertical with extensions and motorized racking mounting, No trip unit, Vertical interleaf
Product Name
Eaton Magnum low voltage power circuit breaker
Catalog Number
MPSC6N3GEAXXSW
UPC
786689630133
Product Length/Depth
16.3 in
Product Height
16.8 in
Product Width
31.1 in
Product Weight
237 lb
Compliances
CE Marked CCC Marked NEMA Compliant SABA Listed
Certifications
ANSI UL Listed Lloyd's Register Certified CSA Certified KEMA Certified DNV GL Certified ABS Certified
Zone selective interlocking application paper
Magnum circuit breakers with Power Xpert Release trip units product aid
Selevctive coordination application paper - IA0120000E3
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Magnum PXR and PD-SB double and double narrow frame UL Certificate of Compliance
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Microsoft Word - Power Xpert Protection Manager Quick Start Guide.docx
Circuit Protection, Power Breakers, Contactors and Fuses, Volume 4, Tab 3
Power Xpert Protection Manager x64 22.6 1
Power Xpert Protection Manager x64 22.6 1
Eaton Specification Sheet - MPSC6N3GEAXXSW
Eaton Specification Sheet - MPSC6N3GEAXXSW
Magnum low-voltage power circuit breakers (ANSI and IEC) renewal parts and accessories
Magnum PXR 20/25 electronic trip units time current curves
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Molded case and low-voltage power circuit breaker health
Feature: Drawout vertical with extensions and motorized racking mounting → Business Impact: Facilitates rapid, safe rack-and-replace operations, reducing maintenance time and exposure. Application: Ideal for motor control centers and switchgear with frequent maintenance cycles. Feature: Three-pole, 6000 A frame with 100 kA short-circuit rating → Business Impact: Robust fault-current protection minimizes arc exposure and equipment damage. Application: Heavy-duty industrial installations and high-current distribution panels. Feature: No trip unit included; compatible with Power Xpert Release trip units → Business Impact: Flexible upgrade path allows tailored protection without replacing hardware. Application: Projects requiring staged protection upgrades or retrofits in existing MCCs. Feature: Dimensions and weight (31.1 in W × 16.8 in H × 16.3 in D; 237 lb) → Business Impact: Space-planning certainty and manageable handling during installation. Application: Panel design and rack layout in compact switchgear. Feature: Global certifications (UL Listed, ANSI, CSA, CE, CCC, KEMA, DNV GL, ABS) → Business Impact: Regulatory confidence supporting cross-border deployments. Application: multinational facilities and supply chains needing standardized protection. Feature: Documentation and support ecosystem (spec sheets, app notes, Protection Manager resources) → Business Impact: Accelerates engineering, commissioning, and maintenance with ready-to-use guidance. Application: Project workflows and technical training for field teams.
Get a Quick Quote for a Eaton MPSC6N3GEAXXSW
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton MPSC6N3GEAXXSW?
Enquire Now
FAQs
The MPSC6N3GEAXXSW is a drawout vertical breaker designed for motor control centers and switchgear. Its motorized racking mounting supports safe insertion and withdrawal, while field-compatibility with Magnum PXR trip units allows staged protection upgrades without a full panel replacement. Ensure the available space matches its 31.1 in width and 16.8 in height within your enclosure.
This breaker features a three-pole configuration with a 6000 A frame and a 100 kA short-circuit rating, offering strong fault-current protection for demanding applications. It is designed for drawout operation and is compatible with Magnum PXR protection units, enabling tailored protection schemes while maintaining robust safety margins.
Yes. The MPSC6N3GEAXXSW is purpose-built for three-pole protection in industrial switchgear, including motor control centers. Its drawout design, motorized racking, and compatibility with Power Xpert Release trip units help simplify MCC protection coordination, reduce commissioning time, and support scalable distribution architectures.
The unit carries UL Listed, ANSI certifications, and additional approvals such as CSA, KEMA, DNV GL, ABS, CE Marked, CCC Marked, and NEMA compliance. These certifications verify safety, reliability, and global acceptance, enabling compliant installations in multinational facilities and cross-border projects.
Benefit drivers include reduced downtime from safer maintenance and faster racking, improved protection accuracy with upgrade paths to Power Xpert Release trip units, and streamlined procurement due to global certifications. While initial cost may be higher, long-term reliability, ease of service, and regulatory compliance contribute to favorable total cost of ownership in heavy-industry environments.